Data Sheet
GE
EBDW020A0B Barracuda™ Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output
STATUS_WORD [0x79]
Command support: full implementation for supported functions (note: Fans, MFR_SPECIFIC, Unknown not supported)
Format
8 bit unsigned (bit field)
Bit Position
Access
15
r
14
r
13
r
12
r
11
r
10
r
9
r
8
r
#PWR_
GOOD
UN
MFR_SPEC1
Function
VOUT
INPUT
FANS1
OTHER1
I/POUT
KNOWN1
Format
8 bit unsigned (bit field)
Bit Position
Access
7
r
6
r
5
r
4
r
3
r
2
r
1
r
0
r
OUTPUT
_OFF
VOUT_O
V _FAULT
VIN_UV
_FAULT
NONE OF
BUSY1
Function
IOUT_OC _FAULT
TEMP
CML
ABOVE1
(1) Not supported
STATUS_VOUT [0x7A]
Command support: VOUT_OV_FAULT support, all bit reset supported
Format
8 bit unsigned (bit field)
Bit Position
Access
7
6
5
4
3
2
1
0
r/reset(1)
r/ reset
r/ reset
r/ reset
r/ reset
VOUT_
MAX
r/ reset
TON_
MAX_
FAULT1
r/ reset
TOFF_
MAX_
WARN1
r/ reset
VOUT
VOUT_OV
_FAULT
VOUT_OV
_WARN1
VOUT_UV
_WARN1
VOUT_UV
_FAULT1
Function
TRACKING
_WARN1
ERROR1
(1) Not supported
STATUS_IOUT [0x7B]
Command support: IOUT_OC_FAULT support, all bit reset supported
Format
8 bit unsigned (bit field)
Bit Position
Access
Function
7
6
5
4
3
2
1
0
r/ reset(1)
r/ reset
r/ reset
r/ reset
r/ reset
r/ reset
In Power
Limiting
Mode1
r/ reset
r/ reset
IOUT_OC IOUT_OC _LV IOUT_OC
_FAULT _WARN
_FAULT1
IOUT_UC Current Share
POUT_OP
_FAULT1
POUT_OP
_WARN1
_FAULT1
Fault1
(1) Not supported
STATUS_INPUT [0x7C]
Command support: VIN_OV_FAULT support, all bit reset supported
Format
8 bit unsigned (bit field)
Bit Position
Access
7
6
5
4
3
2
1
0
r/ reset(1)
r/ reset
r/ reset
r/ reset
r/ reset
Unit Off
(low input
voltage)
r/ reset
r/ reset
r/ reset
VIN_OV
_FAULT
VIN_OV
VIN_UV
VIN_UV
_FAULT
IIN_OC
IIN_OC
PIN_OP
Function
_WARN1
_WARN1
_FAULT1
_WARN1
_WARN1
(1) Not supported
STATUS_TEMPERATURE [0x7D]
Command support: OT_WARN, OT_FAULT supported, all bit reset supported
Format
8 bit unsigned (bit field)
Bit Position
Access
7
6
5
4
3
2
1
0
r/ reset(1)
r/ reset
r/ reset
UT_
r/ reset
UT_
r/ reset
r/ reset
r/ reset
r/ reset
Function
OT_ FAULT
OT_ WARN
reserved
reserved
reserved
reserved
WARN1
FAULT1
(1) Not supported
April 15, 2013
©2012 General Electric Company. All rights reserved.
Page 24