 浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第15页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第16页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第17页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第18页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第20页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第21页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第22页浏览型号EBDW020A0B41-HZ的Datasheet PDF文件第23页  
Data Sheet  
GE  
EBDW020A0B Barracuda™ Series; DC-DC Converter Power Modules  
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output  
Measuring the Temperature using the PMBus  
STATUS_IOUT : Returns one byte of information relating to  
The module can provide temperature information using the  
the status of the module’s output current related faults.  
READ_TEMPERATURE_1 command. The command returns  
Bit Position  
Flag  
Default Value  
two bytes of data in the linear format. The upper five bits  
[7:3] of the high data byte form the two’s complement  
representation of the exponent, which is fixed at –2 (decimal).  
The remaining 11 bits are used for two’s complement  
representation of the mantissa.  
7
6
5
4
3
2
1
0
IOUT OC Fault  
0
0
0
0
0
0
0
0
X
IOUT OC Warning  
X
X
X
X
X
Note that the module’s temperature sensor is located close  
to the module hot spot TH1 (see Thermal Considerations).and  
is subjected to temperatures higher than the ambient air  
temperature near the module. The temperature reading will  
be highly influenced by module load and airflow conditions.  
STATUS_INPUT : Returns one byte of information relating to  
the status of the module’s input voltage related faults.  
Reading the Status of the Module using the PMBus  
Bit Position  
Flag  
Default Value  
The module supports a number of status information  
commands implemented in PMBus. However, not all features  
are supported in these commands. A X in the FLAG cell  
indicates the bit is not supported.  
7
6
5
4
3
2
1
0
VIN OV Fault  
0
0
0
0
0
0
0
0
X
X
VIN UV Fault  
Module Off (Low VIN)  
STATUS_WORD : Returns two bytes of information with a  
summary of the module’s fault/warning conditions.  
High Byte  
X
X
X
Bit Position  
Flag  
Default Value  
15  
14  
13  
12  
11  
10  
9
VOUT fault  
IOUT fault or warning  
Input Voltage fault  
0
0
0
0
0
0
0
0
STATUS_TEMPERATURE : Returns one byte of information  
relating to the status of the module’s temperature related  
faults.  
X
Bit Position  
Flag  
Default Value  
POWER_GOOD# (is negated)  
7
6
5
4
3
2
1
0
OT Fault  
OT Warning  
0
0
0
0
0
0
0
0
X
X
X
X
X
X
X
X
X
8
Low Byte  
Flag  
X
OFF  
Bit Position  
Default Value  
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
VOUT Overvoltage  
IOUT Overcurrent  
VIN Undervoltage  
Temperature  
CML (Comm. Memory Fault)  
X
STATUS_CML : Returns one byte of information relating to the  
status of the module’s communication related faults.  
Bit Position  
Flag  
Default Value  
Invalid/Unsupported  
7
0
Command  
6
5
4
3
2
1
0
Invalid/Unsupported Data  
Packet Error Check Failed  
0
0
0
0
0
0
0
STATUS_VOUT : Returns one byte of information relating to  
the status of the module’s output voltage related faults.  
X
X
X
X
X
Bit Position  
Flag  
Default Value  
7
6
5
4
3
2
1
0
VOUT OV Fault  
0
0
0
0
0
0
0
0
X
X
X
X
X
X
X
April 15, 2013  
©2012 General Electric Company. All rights reserved.  
Page 19  