Specifications ispLSI 2128VE
1
Absolute Maximum Ratings
Supply Voltage V .................................. -0.5 to +5.4V
cc
Input Voltage Applied............................... -0.5 to +5.6V
Off-State Output Voltage Applied ............ -0.5 to +5.6V
Storage Temperature................................ -65 to 150°C
Case Temp. with Power Applied .............. -55 to 125°C
Max. Junction Temp. (T ) with Power Applied ... 150°C
J
1. Stresses above those listed under the “Absolute Maximum Ratings” may cause permanent damage to the device. Functional
operation of the device at these or at any other conditions above those indicated in the operational sections of this specification
is not implied (while programming, follow the programming specifications).
DC Recommended Operating Condition
SYMBOL
PARAMETER
Commercial
Industrial
MIN.
3.0
MAX.
3.6
UNITS
V
V
V
V
T = 0°C to + 70°C
A
VCC
Supply Voltage
3.0
3.6
T = -40°C to + 85°C
A
Input Low Voltage
Input High Voltage
V – 0.5
0.8
VIL
SS
2.0
5.25
VIH
Table 2-0005/2128VE
Capacitance (TA=25°C, f=1.0 MHz)
SYMBOL
PARAMETER
Dedicated Input Capacitance
I/O Capacitance
Clock and Global Output Enable Capacitance
TYPICAL
UNITS
TEST CONDITIONS
VCC = 3.3V, V = 0.0V
8
6
pf
pf
pf
C1
C2
C3
IN
VCC= 3.3V, VI/O = 0.0V
10
VCC= 3.3V, VY = 0.0V
Table 2-0006/2128VE
Erase Reprogram Specifications
PARAMETER
MINIMUM
MAXIMUM
UNITS
Erase/Reprogram Cycles
10,000
–
Cycles
Table 2-0008/2128VE