06 | Keysight | B1505A Power Device Analyzer/Curve Tracer - Data Sheet
Power consumption
HPSMU measurement and output range
Voltage source mode:
Current (mA)
1000
Voltage range
2 V
Power
20 x Ic (W)
20 x Ic (W)
40 x Ic (W)
100 x Ic (W)
200 x Ic (W)
20 V
40 V
100 V
500
200 V
Where Ic is the current compliance setting.
125
50
Current source mode:
Voltage
Power
compliance
-100
-40 -20
100
20 40
-200
200
Vc ≤ 20
20 x Io (W)
40 x Io (W)
100 x Io (W)
200 x Io (W)
-50
Voltage (V)
20 < Vc ≤ 40
40 < Vc ≤ 100
100 < Vc ≤ 200
-125
Where Vc is the voltage compliance set-
ting and lo is output current.
-500
-1000