XMC4500
XMC4000 Family
Electrical Parameters
3.3.10.3 EBU Arbitration Signal Timing
Note: These parameters are not subject to production test, but verified by design and/or
characterization.
Note: Operating Conditions apply.
Table 54
EBU Arbitration Signal Timing Parameters
Parameter
Symbol
Values
Unit Note /
Test Cond
Min. Typ. Max.
ition
Output delay from BFCLKO
rising edge
t1
t2
t3
CC
–
–
–
–
16
–
ns
ns
ns
CL = 50 pF
Data setup to BFCLKO
falling edge
SR 11
–
–
Data hold from BFCLKO
falling edge
SR
2
–
BFCLKO
t1
t1
HLDA Output
BREQ Output
t1
t1
BFCLKO
t3
t3
t2
t2
HOLD Input
HLDA Input
EBU_Arb.vsd
Figure 33
EBU Arbitration Signal Timing
Data Sheet
97
V1.0, 2013-01
Subject to Agreement on the Use of Product Information