TLE9263QX  
System Features  
5.1.3  
SBC Stop Mode  
The SBC Stop Mode is the first level technique to reduce the overall current consumption by setting the voltage  
regulators VCC1, VCC2 and VCC3 into a low-power mode. In this mode VCC1 is still active and supplying the  
microcontroller, which can enter a power down mode. The VCC2 supply, CAN & LIN mode as well as the HSx  
outputs can be configured to stay enabled. All kind of settings have to be done before entering SBC Stop Mode.  
In SBC Stop Mode any kind of SPI WRITE commands are ignored and the SPI_FAIL bit is set, except for changing  
to SBC Normal Mode, triggering a SBC Soft Reset, refreshing the watchdog as well as for reading and clearing  
the SPI status registers. A wake-up event on CAN, LINx and WKx will create an interrupt on pin INT - however,  
no change of the SBC mode will occur. The configuration options are listed below:  
VCC1 is ON  
VCC2 is fixed as configured in SBC Normal Mode  
VCC3 is fixed as configured in SBC Normal Mode  
CAN mode is fixed as configured in SBC Normal Mode  
LIN mode is fixed as configured in SBC Normal Mode  
WK pins are fixed as configured in SBC Normal Mode  
HS Outputs are fixed as configured in SBC Normal Mode  
Cyclic sense is fixed as configured in SBC Normal Mode  
Cyclic wake is fixed as configured in SBC Normal Mode  
Watchdog is fixed as configured in SBC Normal Mode  
SBC Soft Reset can be triggered  
FOx outputs are fixed, i.e. the state from SBC Normal Mode is maintained  
An interrupt is triggered on the pin INT when SBC Stop Mode is entered and not all wake source signalization flags  
from WK_STAT_1 and WK_STAT_2 were cleared.  
Note:If switches are enabled during SBC Stop Mode, e.g. HSx on with or without PWM, then the SBC current  
consumption will increase (see Chapter 4.4).  
Note:It is not possible to switch directly from SBC Stop Mode to SBC Sleep Mode. Doing so will also set the  
SPI_FAIL flag and will bring the SBC into Restart Mode.  
Note:When WK1 and WK2 are configured for the alternate measurement function (WK_MEAS = 1) then the wake  
inputs cannot be selected as wake input sources.  
Data Sheet  
26  
Rev. 1.1, 2014-09-26  