TLE9263QX  
System Features  
5.1.2  
SBC Normal Mode  
The SBC Normal Mode is the standard operating mode for the SBC. All configurations have to be done in SBC  
Normal Mode before entering a low-power mode (see also Chapter 5.1.6 for the device configuration defining the  
Fail-Safe Mode behavior). A wake-up event on CAN, LINx and WKx will create an interrupt on pin INT - however,  
no change of the SBC mode will occur. The configuration options are listed below:  
VCC1 is active  
VCC2 can be switched ON or OFF (default = OFF)  
VCC3 is configurable (OFF coming from SBC Init Mode; as previously programmed coming from SBC Restart  
Mode)  
CAN is configurable (OFF coming from SBC Init Mode; OFF or wake capable coming from SBC Restart Mode,  
see also Chapter 5.1.5)  
LIN is configurable (OFF coming from SBC Init Mode; OFF or wake capable coming from SBC Restart Mode,  
see also Chapter 5.1.5)  
HS Outputs can be switched ON or OFF (default = OFF) or can be controlled by PWM; HS Outputs are OFF  
coming from SBC Restart Mode  
Wake pins show the input level and can be selected to be wake capable (interrupt)  
Cyclic sense can be configured with HS1...4 and Timer1 or Timer 2  
Cyclic wake can be configured with Timer1 or Timer2  
Watchdog is configurable  
All FOx outputs are OFF by default. Coming from SBC Restart Mode FOx can be active (due to a failure event,  
e.g. watchdog trigger failure, VCC1 short circuit, etc.) or inactive (no failure occurred)  
In SBC Normal Mode, there is the possibility of testing the FO outputs, i.e. to verify if setting the FO pin to low will  
create the intended behavior within the system. The FO output can be enabled and then disabled again by the  
microcontroller by setting the FO_ON SPI bit. This feature is only intended for testing purposes.  
Data Sheet  
25  
Rev. 1.1, 2014-09-26  
 复制成功!