TC1767
Electrical Parameters
5.4.4
Quality Declarations
Table 28
Quality Parameters
Symbol
Parameter
Values
Unit Note / Test Condition
Min. Typ. Max.
Operation
Lifetime1)
tOP
–
–
24000 hours –2) 3)
ESD susceptibility VHBM
according to
–
–
2000
V
Conforming to
JESD22-A114-B
Human Body
Model (HBM)
ESD susceptibility VHBM1
of the LVDS pins
–
–
–
–
500
500
V
V
–
ESD susceptibility VCDM
according to
Conforming to
JESD22-C101-C
Charged Device
Model (CDM)
Moisture
Sensitivity Level
MSL
–
–
3
–
Conforming to Jedec
J-STD-020C for 240°C
1) This lifetime refers only to the time when the device is powered on.
2) For worst-case temperature profile equivalent to:
2000 hours at Tj = 150oC
16000 hours at Tj = 125oC
6000 hours at Tj = 110oC
3) This 30000 hours worst-case temperature profile is also covered:
300 hours at Tj = 150oC
1000 hours at Tj = 140oC
1700 hours at Tj = 130oC
24000 hours at Tj = 120oC
3000 hours at Tj = 110oC
Data Sheet
121
V1.3, 2009-09