Register Description
4.2.6
SIP Signaling Code Receive
SSCR
Read
Address 33
H
Value after reset: FF
7
H
0
Only valid in timing mode 0 (SPCR:SPM = 0).
The signaling byte received on SIP can be read from this register.
4.2.7
SIP Signaling Code Transmit
SSCX
Write
Address 33
H
Value after reset: FF
7
H
0
Significant only in timing mode 0 (SPCR:SPM = 0).
The contents of SSCX are continuously output in the signaling byte on SIP (SLD).
4.2.8
SIP Feature Control Read
SFCR
Read
Address 34
H
7
0
Contains the FC data received on SIP (timing mode 0 only, SPCR:SPM = 0).
4.2.9
SIP Feature Control Write
SFCW
Write
Address 34
H
7
0
The byte written into SFCW is output once on SIP in the FC channel (timing mode 0
only, SPCR:SPM = 0).
Semiconductor Group
223