 浏览型号HM5225805BLTT-75的Datasheet PDF文件第23页浏览型号HM5225805BLTT-75的Datasheet PDF文件第24页浏览型号HM5225805BLTT-75的Datasheet PDF文件第25页浏览型号HM5225805BLTT-75的Datasheet PDF文件第26页浏览型号HM5225805BLTT-75的Datasheet PDF文件第28页浏览型号HM5225805BLTT-75的Datasheet PDF文件第29页浏览型号HM5225805BLTT-75的Datasheet PDF文件第30页浏览型号HM5225805BLTT-75的Datasheet PDF文件第31页  
HM5225165B/HM5225805B/HM5225405B-75/A6/B6  
Command Intervals  
Read command to Read command interval:  
1. Same bank, same ROW address: When another read command is executed at the same ROW address  
of the same bank as the preceding read command execution, the second read can be performed after an  
interval of no less than 1 clock. Even when the first command is a burst read that is not yet finished, the data  
read by the second command will be valid.  
READ to READ Command Interval (same ROW address in same bank)  
CLK  
Command  
READ  
ACTV  
Row  
READ  
Column B  
Column A  
Address  
BS  
Dout  
out A0  
out B2 out B3  
out B0 out B1  
CAS Latency = 3  
Burst Length = 4  
Bank 0  
Column =B  
Dout  
Bank0  
Active  
Column =A Column =B Column =A  
Read Read Dout  
2. Same bank, different ROW address: When the ROW address changes on same bank, consecutive read  
commands cannot be executed; it is necessary to separate the two read commands with a precharge command  
and a bank-active command.  
3. Different bank: When the bank changes, the second read can be performed after an interval of no less  
than 1 clock, provided that the other bank is in the bank-active state. Even when the first command is a burst  
read that is not yet finished, the data read by the second command will be valid.  
READ to READ Command Interval (different bank)  
CLK  
Command  
READ READ  
ACTV  
Row 0  
ACTV  
Column A  
Row 1  
Column B  
Address  
BS  
Dout  
out A0  
out B2 out B3  
out B0 out B1  
Bank3  
Dout  
Bank0  
Dout  
CAS Latency = 3  
Burst Length = 4  
Bank0  
Active  
Bank3 Bank0 Bank3  
Active Read Read  
Data Sheet E0082H10  