4.0 Registers  
RS8953B/8953SPB  
4.11 Common Command  
HDSL Channel Unit  
0xF3—Command Register 6 (CMD_6)  
7
6
5
4
3
2
1
0
RAZ_[1:3]  
RAUX_EN  
RSIG_EN  
MSYNC_MEAS  
BER_SEL[1:0]  
BER_SEL[1:0]  
BER/PRBS Mode—Selects the BER meter source, the PRBS generator output direction, and  
serial or framed data formats. Refer to Figure 3-12.  
BER_SEL  
00  
Mode  
Normal  
Mode Description  
PRBS outputs data under control of ROUTE_TBL.  
BER monitors data selected by COMBINE_TBL.  
Reserved  
01  
10  
PCM Framed PRBS outputs data under control of ROUTE_TBL.  
BER monitors TSER during the same timeslots  
selected by ROUTE_TBL. TCLK and RCLK must  
be identical. If accompanied by loopback on HDSL  
side, framed PCM channels are tested.  
11  
PCM Serial PRBS output replaces RSER data. BER monitors  
all data at TSER. TCLK and RCLK must be  
identical.  
MSYNC_MEAS  
RSIG_EN  
MSYNC Phase Measurement—Selects whether TMSYNC or RMSYNC phase is measured  
with respect to MSYNC. The result is reported in MSYNC_PHS [addr 0x39].  
0 = TMSYNC to MSYNC phase measurement  
1 = RMSYNC to MSYNC phase measurement  
Receive Signaling Table Enable—Applicable only for an LTU in a P2MP application. When  
active, the Receive Signaling Table [RSIG_TBL; addr 0xF2] grooms the ABCD signaling  
from two or three remote sites and routes the groomed signal via DBANK_3 in the receive  
Combination Table [COMBINE_TBL; addr 0xEE]. When inactive, RSIG_TBL is unused and  
the receive combination table regains use of DBANK_3.  
0 = Normal receive  
1 = Enable receive signaling table  
RAUX_EN  
Receive Auxiliary Enable—The RAUX1–RAUX3 outputs share the same pins with DROP,  
INSERT, and MSYNC, respectively. RAUX_EN determines which signals are output on these  
shared pins.  
0 = DROP, INSERT, or MSYNC outputs enabled  
1 = RAUXn outputs enabled  
RAZ_1–RAZ_3  
Receive Auxiliary Z-bit Enable—Applicable only when RAUX_EN is active. RAZn  
(n = 1,2,3) selects whether ROHn marks the output of all overhead and Z-bits or the output of  
only the last 40 Z-bits. If enabled, ROHn is high for one BCLKn, coincident with each of the  
last 40 Z-bits output on RAUXn. Otherwise, all data passed into the RFIFO is marked high by  
ROHn.  
0 = ROHn marks all non-payload data  
1 = ROHn marks only the last 40 Z-bits  
4-48  
Conexant  
N8953BDSB