CS5463
6.1.17 Reactive Power Register ( QTrig
)
Address: 24
MSB
LSB
-1
-2
-3
-4
-5
-6
-7
-17
-18
-19
-20
-21
-22
-23
0
.....
2
2
2
2
2
2
2
2
2
2
2
2
2
2
The Reactive Power (Q ) is calculated using trigonometric identities. (See Section 4.3 Power Measurements
Trig
on page 14). The value is represented in unsigned notation and in the range of 0 ≤ S < 1.0, with the binary point
to the right of the MSB.
6.1.18 Power Factor Register ( PF )
Address: 25
MSB
LSB
0
-1
-2
-3
-4
-5
-6
-7
-17
-18
-19
-20
-21
-22
-23
.....
-(2 )
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Power Factor is calculated by dividing the Active (Real) Power by Apparent Power. The value is represented in
two's complement notation and in the range of -1.0 ≤ PF< 1.0, with the binary point to the right of the MSB.
6.1.19 Apparent Power Register ( S )
Address: 27
MSB
LSB
-1
-2
-3
-4
-5
-6
-7
-17
-18
-19
-20
-21
-22
-23
0
.....
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Apparent power (S) is the product of the V
and I
, The value is represented in unsigned notation and in
RMS
RMS
the range of 0 ≤ S < 1.0, with the binary point to the right of the MSB.
32