欢迎访问ic37.com |
会员登录 免费注册
发布采购

AS4SD4M16DG-10/XT 参数 Datasheet PDF下载

AS4SD4M16DG-10/XT图片预览
型号: AS4SD4M16DG-10/XT
PDF下载: 下载PDF文件 查看货源
内容描述: 4梅格×16 SDRAM同步动态随机存取存储 [4 Meg x 16 SDRAM Synchronous DRAM Memory]
分类和应用: 存储内存集成电路光电二极管动态存储器时钟
文件页数/大小: 50 页 / 1139 K
品牌: AUSTIN [ AUSTIN SEMICONDUCTOR ]
 浏览型号AS4SD4M16DG-10/XT的Datasheet PDF文件第6页浏览型号AS4SD4M16DG-10/XT的Datasheet PDF文件第7页浏览型号AS4SD4M16DG-10/XT的Datasheet PDF文件第8页浏览型号AS4SD4M16DG-10/XT的Datasheet PDF文件第9页浏览型号AS4SD4M16DG-10/XT的Datasheet PDF文件第11页浏览型号AS4SD4M16DG-10/XT的Datasheet PDF文件第12页浏览型号AS4SD4M16DG-10/XT的Datasheet PDF文件第13页浏览型号AS4SD4M16DG-10/XT的Datasheet PDF文件第14页  
SDRAM  
AS4SD4M16  
Austin Semiconductor, Inc.  
COMMAND INHIBIT  
The COMMAND INHIBIT function prevents new  
WRITE  
The WRITE command is used to initiate a burst write  
commands from being executed by the SDRAM, regardless of access to an active row. The value on the BA0, BA1 inputs  
whether the CLK signal is enabled. The SDRAM is effectively selects the bank, and the address provided on inputs A0-A7  
deselected. Operations already in progress are not affected.  
(x16) selects the starting column location. The value on input  
A10 determines whether or not AUTO PRECHARGE is used. If  
AUTO PRECHARGE is selected, the row being accessed will  
NO OPERATION (NOP)  
The NO OPERATION (NOP) command is used to per- be precharged at the end of the WRITE burst; if AUTO  
form a NOP to an SDRAM which is selected (CS\ is LOW). This PRECHARGE is not selected, the row will remain open for sub-  
prevents unwanted commands from being registered during sequent accesses. Input data appearing on the DQs is written  
idle or wait states. Operations already in progress are not af- to the memory array subject to the DQM input logic level ap-  
fected.  
pearing coincident with the data. If a given DQM signal is  
registered LOW, the corresponding data will be written to  
memory; if the DQM signal is registered HIGH, the correspond-  
LOAD MODE REGISTER  
The Mode Register is loaded via inputs A0-A11. See ing data inputs will be ignored, and a WRITE will not be ex-  
Mode Register heading in the Register Definition section. The ecuted to that byte/column location.  
LOAD MODE REGISTER command can only be issued when  
all banks are idle, and a subsequent executable command can- PRECHARGE  
not be issued until tMRD is met.  
The PRECHARGE command is used to deactivate the  
open row in a particular bank or the open row in all banks. The  
bank(s) will be available for a subsequent row access a speci-  
ACTIVE  
The ACTIVE command is used to open (or activate) a  
fied time (tRP) after the PRECHARGE command is issued. Input  
A10 determines whether one or all banks are to be precharged,  
and in the case where only one bank is to be precharged, inputs  
BA0, BA1 select the bank. Otherwise BA0, BA1 are treated as  
“Don’t Care.” Once a bank has been precharged, it is in the idle  
state and must be activated prior to any READ or WRITE com-  
mands being issued to that bank.  
row in a particular bank for a subsequent access. The value on  
the BA0, BA1 inputs selects the bank, and the address pro-  
vided on inputs A0-A11 selects the row. This row remains ac-  
tive (or open) for accesses until a PRECHARGE command is  
issued to that bank. A PRECHARGE command must be issued  
before opening a different row in the same bank.  
READ  
AUTO PRECHARGE  
The READ command is used to initiate a burst read  
access to an active row. The value on the BA0, BA1 inputs  
selects the bank, and the address provided on inputs A0-A7  
(x16) selects the starting column location. The value on input  
A10 determines whether or not AUTO PRECHARGE is used. If  
AUTO PRECHARGE is selected, the row being accessed will  
be precharged at the end of the READ burst; if AUTO  
PRECHARGE is not selected, the row will remain open for sub-  
sequent accesses. Read data appears on the DQs subject to  
the logic level on the DQM inputs two clocks earlier. If a given  
DQM signal was registered HIGH, the corresponding DQs will  
be High-Z two clocks later; if the DQM signal was registered  
LOW, the DQs will provide valid data.  
AUTO PRECHARGE is a feature which performs the  
same individual-bank PRECHARGE function described above,  
without requiring an explicit command. This is accomplished  
by using A10 to enable AUTO PRECHARGE in conjunction  
with a specific READ or WRITE command. A precharge of the  
bank/row that is addressed with the READ or WRITE com-  
mand is automatically performed upon completion of the READ  
or WRITE burst, except in the full-page burst mode, where  
AUTO PRECHARGE does not apply. AUTO PRECHARGE is  
nonpersistent in that it is either enabled or disabled for each  
individual READ or WRITE command.  
AUTO PRECHARGE ensures that the precharge is  
initiated at the earliest valid stage within a burst. The user must  
not issue another command to the same bank until the precharge  
time (tRP) is completed. This is determined as if an explicit  
PRECHARGE command was issued at the earliest possible time,  
as described for each burst type in the Operation section of this  
data sheet.  