欢迎访问ic37.com |
会员登录 免费注册
发布采购

ATMEGA64A-AU 参数 Datasheet PDF下载

ATMEGA64A-AU图片预览
型号: ATMEGA64A-AU
PDF下载: 下载PDF文件 查看货源
内容描述: 8位微控制器,带有64K字节的系统内可编程闪存 [8-bit Microcontroller with 64K Bytes In-System Programmable Flash]
分类和应用: 闪存微控制器
文件页数/大小: 392 页 / 7964 K
品牌: ATMEL [ ATMEL ]
 浏览型号ATMEGA64A-AU的Datasheet PDF文件第138页浏览型号ATMEGA64A-AU的Datasheet PDF文件第139页浏览型号ATMEGA64A-AU的Datasheet PDF文件第140页浏览型号ATMEGA64A-AU的Datasheet PDF文件第141页浏览型号ATMEGA64A-AU的Datasheet PDF文件第143页浏览型号ATMEGA64A-AU的Datasheet PDF文件第144页浏览型号ATMEGA64A-AU的Datasheet PDF文件第145页浏览型号ATMEGA64A-AU的Datasheet PDF文件第146页  
ATmega64A  
• Bit 5 – ICF3: Timer/Counter3, Input Capture Flag  
This flag is set when a capture event occurs on the ICP3 pin. When the Input Capture Register  
(ICR3) is set by the WGM3:0 to be used as the TOP value, the ICF3 flag is set when the counter  
reaches the TOP value.  
ICF3 is automatically cleared when the Input Capture 3 Interrupt Vector is executed. Alterna-  
tively, ICF3 can be cleared by writing a logic one to its bit location.  
• Bit 4 – OCF3A: Timer/Counter3, Output Compare A Match Flag  
This flag is set in the timer clock cycle after the counter (TCNT3) value matches the Output  
Compare Register A (OCR3A).  
Note that a Forced Output Compare (FOC3A) strobe will not set the OCF3A flag.  
OCF3A is automatically cleared when the Output Compare Match 3 A Interrupt Vector is exe-  
cuted. Alternatively, OCF3A can be cleared by writing a logic one to its bit location.  
• Bit 3 – OCF3B: Timer/Counter3, Output Compare B Match Flag  
This flag is set in the timer clock cycle after the counter (TCNT3) value matches the Output  
Compare Register B (OCR3B).  
Note that a Forced Output Compare (FOC3B) strobe will not set the OCF3B flag.  
OCF3B is automatically cleared when the Output Compare Match 3 B Interrupt Vector is exe-  
cuted. Alternatively, OCF3B can be cleared by writing a logic one to its bit location.  
• Bit 2 – TOV3: Timer/Counter3, Overflow Flag  
The setting of this flag is dependent of the WGM3:0 bits setting. In Normal and CTC modes, the  
TOV3 flag is set when the timer overflows. Refer to Table 14-2 on page 106 for the TOV3 flag  
behavior when using another WGM3:0 bit setting.  
TOV3 is automatically cleared when the Timer/Counter3 Overflow Interrupt Vector is executed.  
Alternatively, OCF3B can be cleared by writing a logic one to its bit location.  
• Bit 1 – OCF3C: Timer/Counter3, Output Compare C Match Flag  
This flag is set in the timer clock cycle after the counter (TCNT3) value matches the Output  
Compare Register C (OCR3C).  
Note that a Forced Output Compare (FOC3C) strobe will not set the OCF3C flag.  
OCF3C is automatically cleared when the Output Compare Match 3 C Interrupt Vector is exe-  
cuted. Alternatively, OCF3C can be cleared by writing a logic one to its bit location.  
• Bit 0 – OCF1C: Timer/Counter1, Output Compare C Match Flag  
This flag is set in the timer clock cycle after the counter (TCNT1) value matches the Output  
Compare Register C (OCR1C).  
Note that a Forced Output Compare (FOC1C) strobe will not set the OCF1C flag.  
OCF1C is automatically cleared when the Output Compare Match 1 C Interrupt Vector is exe-  
cuted. Alternatively, OCF1C can be cleared by writing a logic one to its bit location.  
142  
8160C–AVR–07/09  
 复制成功!