Agilent 41501B SMU and Pulse Generator Expander  
HPSMU (High Power SMU) Specifications  
Output Terminal/Connection:  
Dual triaxial connectors, Kelvin (remote  
sensing)  
Voltage Range, Resolution, and Accuracy (HPSMU)  
Voltage Set.  
Set. Accuracy  
Meas. Meas. Accuracy  
Reso.  
Max.  
Range  
2 V  
Reso.  
Current  
Voltage/Current Compliance  
(Limiting):  
100 μV (0.03ꢀ%+00 μV)  
2 μV  
(0.02ꢀ%700 μV)  
(0.02ꢀ%2 mV)  
(0.02ꢀ%3 mV)  
(0.03ꢀ%5 mV)  
(0.035ꢀ%10 mV)  
1 A  
1 A  
500 mA  
125 mA  
50 mA  
20 V  
40 V  
100 V 5 mV  
200 V 10mV  
1 mV  
2 mV  
(0.03ꢀ%4 mV)  
(0.03ꢀ%7 mV)  
(0.04ꢀ%15 mV)  
(0.045ꢀ%30 mV)  
20 μV  
40 μV  
100 μV  
200 μV  
Voltage: 0 V to 200 V  
Current: 1 pA to 1 A  
Compliance Accuracy: Same as the current  
(voltage) settling accuracy.  
HPSMU Supplemental Information:  
Maximum allowable cable resistance when  
using Kelvin connection:  
Current Range, Resolution, and Accuracy (HPSMU)  
Current Set.  
Set.Accuracy  
Meas. Meas. Accuracy  
Reso.  
Max. V  
Range  
1 nA  
10 nA 1 pA  
100 nA 10 pA  
1 μA  
Reso.  
100 fA  
Force: 0.7 Ω (100 mA to 1 A)  
Force: 10 Ω (≤100 mA)  
(0.5ꢀ%3 pA%2 fAꢁVout)  
(0.5ꢀ%7 pA%20 fAꢁVout)  
(0.12ꢀ%50 pA%200 fAꢁVout) 100 fA  
10 fA  
10 fA  
(0.5ꢀ%3 pA%2 fAꢁVout)  
(0.5ꢀ%5 pA%20 fAꢁVout)  
(0.1ꢀ%30 pA%200 fAꢁVout) 200 V  
(0.1ꢀ%200 pA%2 pAꢁVout) 200 V  
200 V  
200 V  
Sense: 10 Ω  
Typical voltage source output resistance  
(Force line/non-Kelvin connection): 0.2 Ω  
Voltage measurement input resistance/  
current source output resistance:  
≥1013 Ω (1 nA range)  
100 pA (0.12ꢀ%400 pA%2 pAꢁVout) 1 pA  
10 μA 1 nA  
100 μA 10 nA  
(0.12ꢀ%5 nA%20 pAꢁVout)  
(0.12ꢀ%40 nA%200 pAꢁVout) 100 pA  
10 pA  
(0.1ꢀ%3 nA%20 pAꢁVout)  
(0.1ꢀ%20 nA%200 pAꢁVout 200 V  
(0.1ꢀ%300 nA%2 nAꢁVout) 200 V  
200 V  
1 mA  
100 nA (0.12ꢀ%500 nA%2 nAꢁVout) 1 nA  
10 mA 1 μA  
100 mA 10 μA  
1 A  
(0.12ꢀ%4 μA%20 nAꢁVout)  
(0.12ꢀ%50 μA%200 nAꢁVout) 100 nA  
100 μA (0.5ꢀ%500 μA%2 μAꢁVout) 1 μA  
10 nA  
(0.1ꢀ%2 μA%20 nAꢁVout)  
(0.1ꢀ%30 μA%200 nAꢁVout)  
(0.5ꢀ%300 μA%2 μAꢁVout)  
200 V  
Current compliance setting accuracy for  
opposite polarity:  
1
2
1 nA to 10 nA range: V/I setting  
accuracy 12ꢀ of range  
1 200 V (Iout ≤50 mA), 100 V (50 mA<Iout≤100 mA)  
2 200 V (Iout ≤50 mA), 100 V (50 mA<Iout≤125 mA), 40 V (125 mA<Iout≤500 mA), 20 V (500 mA<Iout≤1 mA)  
100 nA to 1 A range: V/I setting  
accuracy 2.5ꢀ of range  
Vout is the output voltage in volts. Iout is the output current in amps. For example, accuracy specifications  
are given as ꢀ of set/measured value (0.1ꢀ) plus offset value (30 pA%200 fAꢁVout) for the 100 nA range.  
The offset value consists of a fixed part determined by the set/measurement range and a proportional part  
that is multiplied by Vout.  
Current (mA)  
1000  
500  
HPSMU measurement  
and output range  
125  
50  
-200  
-100  
-40 -20  
20  
40  
100  
200  
-50  
-125  
Voltage (V)  
-500  
-1000  
4