 浏览型号EVAL-AD7366CBZ的Datasheet PDF文件第20页浏览型号EVAL-AD7366CBZ的Datasheet PDF文件第21页浏览型号EVAL-AD7366CBZ的Datasheet PDF文件第22页浏览型号EVAL-AD7366CBZ的Datasheet PDF文件第23页浏览型号EVAL-AD7366CBZ的Datasheet PDF文件第24页浏览型号EVAL-AD7366CBZ的Datasheet PDF文件第25页浏览型号EVAL-AD7366CBZ的Datasheet PDF文件第26页浏览型号EVAL-AD7366CBZ的Datasheet PDF文件第28页  
AD7366/AD7367  
APPLICATION HINTS  
To avoid radiating noise to other sections of the board, com-  
ponents, such as clocks, with fast switching signals should be  
shielded with digital ground and should never be run near the  
analog inputs. Avoid crossover of digital and analog signals. To  
reduce the effects of feedthrough within the board, traces should  
be run at right angles to each other. A microstrip technique is  
the best method, but its use may not be possible with a double-  
sided board. In this technique, the component side of the board  
is dedicated to ground planes, and signals are placed on the  
other side.  
LAYOUT AND GROUNDING  
The printed circuit board that houses the AD7366/AD7367  
should be designed so that the analog and digital sections are  
confined to their own separate areas of the board. This design  
facilitates the use of ground planes that can be easily separated.  
To provide optimum shielding for ground planes, a minimum  
etch technique is generally the best option. All AGND pins on  
the AD7366/AD7367 should be connected to the AGND plane.  
Digital and analog ground pins should be joined in only one  
place. If the AD7366/AD7367 are in a system where multiple  
devices require an AGND and DGND connection, the connec-  
tion should still be made at only one point. A star point should  
be established as close as possible to the ground pins on the  
AD7366/AD7367.  
Good decoupling is also important. All analog supplies should  
be decoupled with 1ꢀ ꢃF tantalum capacitors in parallel with  
ꢀ.1 ꢃF capacitors to AGND. To achieve the best results from  
these decoupling components, they must be placed as close as  
possible to the device, ideally right up against the device. The  
ꢀ.1 ꢃF capacitors should have a low effective series resistance  
(ESR) and low effective series inductance (ESI), such as is typical  
of common ceramic and surface mount types of capacitors. These  
low ESR, low ESI capacitors provide a low impedance path to  
ground at high frequencies to handle transient currents due to  
internal logic switching.  
Good connections should be made to the power and ground  
planes. This can be done with a single via or multiple vias for  
each supply and ground pin.  
Avoid running digital lines under the AD7366/AD7367 devices  
because this couples noise onto the die. However, the analog  
ground plane should be allowed to run under the AD7366/  
AD7367 to avoid noise coupling. The power supply lines to  
the AD7366/AD7367 should use as large a trace as possible to  
provide low impedance paths and reduce the effects of glitches  
on the power supply line.  
Rev. 0 | Page 27 of 28  
 