ADM3055E/ADM3057E
Data Sheet
REGULATORY INFORMATION
ADM3055E
See Table 11 and the Insulation Lifetime section for details regarding maximum working voltages for specific cross isolation waveforms
and insulation levels. The ADM3055E is approved or pending approval by the organizations listed in Table 5.
Table 5.
UL (Pending)1
CSA (Pending)
VDE (Pending)2
CQC (Pending)
Recognized under 1577
Component Recognition
Program1
Approved under CSA Component
Acceptance Notice 5A
DIN V VDE V 0884-10
(VDE V 0884-10):2006-12
Certified under
CQC11-471543-2012
Single Protection, 5000 V rms CSA 60950-1-07+A1+A2 and
Reinforced insulation 849 VPEAK, surge GB4943.1-2011: basic
isolation voltage (VIOTM) = 8000 VPEAK
insulation at 830 V rms
(1174 VPEAK
Reinforced insulation at
415 V rms (587 VPEAK
Isolation Voltage
IEC 60950-1, second edition, +A1+A2
Basic insulation at 830 V rms (1174 VPEAK
Reinforced insulation at 415 V rms
)
)
)
(587 VPEAK
)
IEC 60601-1 Edition 3.1:
Basic insulation (1 MOPP), 519 V rms
(734 VPEAK
Reinforced insulation (2 MOPP), 261V rms
(369 VPEAK
)
)
CSA 61010-1-12 and IEC 61010-1 third
edition
Basic insulation at 300 V rms mains,
830 V secondary (1174 VPEAK
)
Reinforced insulation at 300 V rms mains,
415 V secondary (587 VPEAK
)
File E214100
File 205078
File 2471900-4880-0001
File (pending)
1 In accordance with UL 1577, each ADM3055E is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 sec.
2 In accordance with DIN V VDE V 0884-10, each ADM3055E is proof tested by applying an insulation test voltage ≥ 1592 VPEAK for 1 sec (partial discharge detection limit =
5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval.
Rev. A | Page 8 of 24