欢迎访问ic37.com |
会员登录 免费注册
发布采购

ADM3055E 参数 Datasheet PDF下载

ADM3055E图片预览
型号: ADM3055E
PDF下载: 下载PDF文件 查看货源
内容描述: [Signal and Power Isolated, CAN Transceivers for CAN FD]
分类和应用:
文件页数/大小: 24 页 / 454 K
品牌: ADI [ ADI ]
 浏览型号ADM3055E的Datasheet PDF文件第4页浏览型号ADM3055E的Datasheet PDF文件第5页浏览型号ADM3055E的Datasheet PDF文件第6页浏览型号ADM3055E的Datasheet PDF文件第7页浏览型号ADM3055E的Datasheet PDF文件第9页浏览型号ADM3055E的Datasheet PDF文件第10页浏览型号ADM3055E的Datasheet PDF文件第11页浏览型号ADM3055E的Datasheet PDF文件第12页  
ADM3055E/ADM3057E  
Data Sheet  
REGULATORY INFORMATION  
ADM3055E  
See Table 11 and the Insulation Lifetime section for details regarding maximum working voltages for specific cross isolation waveforms  
and insulation levels. The ADM3055E is approved or pending approval by the organizations listed in Table 5.  
Table 5.  
UL (Pending)1  
CSA (Pending)  
VDE (Pending)2  
CQC (Pending)  
Recognized under 1577  
Component Recognition  
Program1  
Approved under CSA Component  
Acceptance Notice 5A  
DIN V VDE V 0884-10  
(VDE V 0884-10):2006-12  
Certified under  
CQC11-471543-2012  
Single Protection, 5000 V rms CSA 60950-1-07+A1+A2 and  
Reinforced insulation 849 VPEAK, surge GB4943.1-2011: basic  
isolation voltage (VIOTM) = 8000 VPEAK  
insulation at 830 V rms  
(1174 VPEAK  
Reinforced insulation at  
415 V rms (587 VPEAK  
Isolation Voltage  
IEC 60950-1, second edition, +A1+A2  
Basic insulation at 830 V rms (1174 VPEAK  
Reinforced insulation at 415 V rms  
)
)
)
(587 VPEAK  
)
IEC 60601-1 Edition 3.1:  
Basic insulation (1 MOPP), 519 V rms  
(734 VPEAK  
Reinforced insulation (2 MOPP), 261V rms  
(369 VPEAK  
)
)
CSA 61010-1-12 and IEC 61010-1 third  
edition  
Basic insulation at 300 V rms mains,  
830 V secondary (1174 VPEAK  
)
Reinforced insulation at 300 V rms mains,  
415 V secondary (587 VPEAK  
)
File E214100  
File 205078  
File 2471900-4880-0001  
File (pending)  
1 In accordance with UL 1577, each ADM3055E is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 sec.  
2 In accordance with DIN V VDE V 0884-10, each ADM3055E is proof tested by applying an insulation test voltage ≥ 1592 VPEAK for 1 sec (partial discharge detection limit =  
5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval.  
Rev. A | Page 8 of 24  
 
 
 复制成功!