TABLE IIB. Delta limits at +25°C.
Device types
Test 1/
All
IDD
IOZ
±1.0 mA
±2.0 µA
±10 ns
tPBLH, tPBHL
1/ The above parameters shall be recorded before and after the required
burn-in and life test to determine the delta.
6.5 Abbreviations, symbols, and definitions. The abbreviations, symbols, and definitions used herein are defined in MIL-PRF-
38535 and MIL-HDBK-1331.
6.5.1 Timing limits. The table of timing values shows either a minimum or a maximum limit for each parameter. Input
requirements are specified from the external system point of view. Thus, address setup time is shown as a minimum since the
system must supply at least that much time (even though most devices do not require it). On the other hand, responses from
the memory are specified from the device point of view. Thus, the access time is shown as a maximum since the device never
provides data later than that time.
6.5.2 Waveforms.
Waveform
symbol
Input
Output
MUST BE
WILL BE
VALID
VALID
CHANGE FROM
H TO L
WILL CHANGE
FROM
H TO L
CHANGE FROM
L TO H
WILL CHANGE
FROM
L TO H
DON'T CARE
ANY CHANGE
PERMITTED
CHANGING
STATE
UNKNOWN
HIGH
IMPEDANCE
6.6 Sources of supply.
6.6.1 Sources of supply for device classes Q and V. Sources of supply for device classes Q and V are listed in QML-38535.
The vendors listed in QML-38535 have submitted a certificate of compliance (see 3.6 herein) to DSCC-VA and have agreed to
this drawing.
6.6.2 Approved sources of supply for device class M. Approved sources of supply for class M are listed in MIL-HDBK-103. The
vendors listed in MIL-HDBK-103 have agreed to this drawing and a certificate of compliance (see 3.6 herein) has been submitted
to and accepted by DSCC-VA.
SIZE
STANDARD
5962-90965
A
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
REVISION LEVEL
G
SHEET
18
DSCC FORM 2234