 浏览型号5962-9096501MZX的Datasheet PDF文件第12页浏览型号5962-9096501MZX的Datasheet PDF文件第13页浏览型号5962-9096501MZX的Datasheet PDF文件第14页浏览型号5962-9096501MZX的Datasheet PDF文件第15页浏览型号5962-9096501MZX的Datasheet PDF文件第17页浏览型号5962-9096501MZX的Datasheet PDF文件第18页浏览型号5962-9096501MZX的Datasheet PDF文件第19页浏览型号5962-9096501MZX的Datasheet PDF文件第20页  
4.4.4.2 Single event phenomena (SEP). SEP testing shall be required on class V devices. SEP testing shall be performed on  
the Standard Evaluation Circuit (SEC) or alternate SEP test vehicle as approved by the qualifying activity at initial qualification  
and after any design or process changes which may affect the upset or latchup characteristics. Test four devices with zero  
failures. ASTM standard F1192 may be used as a guideline when performing SEP testing. The test conditions for SEP are as  
follows:  
a. The package lid of the DUT is removed so as to provide an unobstructed path to the die for the ion beam.  
b. The DUT is biased or exercised as appropriate to that IC being tested.  
c. The temperature that SEP tests are conducted at is 25°C +/- 10°C (ambient).  
d. Particle penetration range is > 20 microns (Si).  
e. The flux used is between 1E2 and 1E5 ions/cm2/s.  
f. The beam incidence angle(s) used are between 0° to 60° from normal.  
g. Supply current and voltage(s) as well as SEU, SEL and faults are monitored and recorded in-situ.  
h. For SEP test limits, see Table IB herein.  
4.5 Delta measurements for device class V. Delta measurements, as specified in table IIA, shall be made and recorded before  
and after the required burn-in screens and steady-state life tests to determine delta compliance. The electrical parameters to be  
measured, with associated delta limits are listed in table IIB. The device manufacturer may, at his option, either perform delta  
measurements or within 24 hours after burn-in perform final electrical parameter tests, subgroups 1, 7,  
and 9.  
4.6 Programming procedures. The programming procedures shall be as specified by the device manufacturer and shall be  
made available upon request.  
5. PACKAGING  
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-STD-883 (see 3.1 herein) for  
device class M and MIL-PRF-38535 for device classes Q and V.  
6. NOTES  
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications  
(original equipment), design applications, and logistics purposes.  
6.1.1 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor  
prepared specification or drawing.  
6.1.2 Substitutability. Device class Q devices will replace device class M devices.  
6.2 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated with the users of record for  
the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal.  
6.3 Record of users. Military and industrial users should inform Defense Supply Center Columbus (DSCC) when a system  
application requires configuration control and which SMD's are applicable to that system. DSCC will maintain a record of users  
and this list will be used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronic  
devices (FSC 5962) should contact DSCC-VA, telephone (614) 692-0544.  
6.4 Comments. Comments on this drawing should be directed to DSCC-VA , Columbus, Ohio 43218-3990, or telephone  
(614) 692-0547.  