8
Electrical Specifications (DC)
Over recommended operating conditions (TA = -40 to 100°C, IF(ON) = 7 to 16 mA, VF(OFF) = -3.0 to 0.8 V,
VCC = 15 to 30 V, VEE = Ground) unless otherwise specified.
Parameter
Symbol
Device
Min.
0.5
Typ.*
Max. Units Test Conditions
Fig. Note
High Level
Output Current
IOH
1.5
A
A
A
A
V
VO = (VCC - 4 V)
VO = (VCC - 15 V)
2, 3,
17
5
2
2.0
Low Level
Output Current
IOL
0.5
2.0
VO = (VEE + 2.5 V) 5, 6,
5
2.0
VO = (VEE + 15 V)
IO = -100 mA
18
2
High Level
Output Voltage
VOH
VOL
(VCC - 4) (VCC - 3)
1, 3,
19
6, 7
Low Level
Output Voltage
0.1
2.5
2.5
0.5
5.0
5.0
V
IO = 100 mA
4, 6,
20
High Level
Supply Current
ICCH
ICCL
IFLH
mA Output Open,
IF = 7 to 16 mA
7, 8
Low Level
Supply Current
mA Output Open,
VF = -3.0 to +0.8 V
Threshold Input
Current Low
to High
HCPL-3120
HCPL-J312
HCNW3120
2.3
1.0
2.3
5.0
8.0
mA IO = 0 mA,
VO > 5 V
9, 15,
21
Threshold Input
Voltage High
to Low
VFHL
0.8
V
Input Forward
Voltage
VF
HCPL-3120
HCPL-J312
HCNW3120
1.2
1.5
1.6
1.8
1.95
V
IF = 10 mA
16
Temperature
Coefficient
of Forward
Voltage
∆VF/∆TA HCPL-3120
HCPL-J312
-1.6
-1.3
mV/°C IF = 10 mA
HCNW3120
Input Reverse
Breakdown
Voltage
BVR
CIN
HCPL-3120
HCPL-J312
HCNW3120
5
3
V
pF
V
IR = 10 µA
IR = 100 µA
Input
Capacitance
HCPL-3120
HCPL-J312
HCNW3120
60
70
f = 1 MHz,
VF = 0 V
UVLO Threshold VUVLO+
11.0
9.5
12.3
13.5
12.0
VO > 5 V,
IF = 10 mA
22,
34
VUVLO–
10.7
1.6
UVLO Hysteresis UVLOHYS
*All typical values at TA = 25°C and VCC - VEE = 30 V, unless otherwise noted.