Data Sheet
June 2002
TMXF28155 Supermapper
155/51 Mbits/s SONET/SDH x28/x21 DS1/E1
12 28-Channel Framer Registers (continued)
Table 399. FRM_PMLR6, Performance Monitor Link Register 6 (COR)
Address* Bit
Name
Function
Reset
Default
0x8LP85 15:5
4
RSVD
Reserved.
0
0
FRM_FDL_RAI
ESF_FDL_RAI/Yellow Alarm. A 1 indicates the receive
framer detected the ESF_FDL_RAI/yellow alarm code in the
payload. This code is defined in ANSI T1.403-1995 as a
00000000 11111111 pattern in the facility data link (received
right-to-left). This signal is set when the pattern is detected
(10 consecutive times) and is cleared when it is read if the pat-
tern is no longer being detected.
3
FRM_FDL_PLBON ESF_FDL Payload Loopback Enable. A 1 indicates the
receive framer detected the ESF_FDL payload loopback
enable code in the payload. This code is defined in
0
ANSI T1.403-1995 as a 00010100 11111111 pattern in the
facility data link (received right-to-left). This signal is set when
the pattern is detected (10 consecutive times) and is cleared
when it is read if the pattern is no longer being detected. This
could also be set by FF_PLB (manual PLB indication) input.
2
1
0
FRM_FDL_PLBOFF ESF_FDL Payload Loopback Disable. A 1 indicates the
receive framer detected the ESF_FDL payload loopback dis-
able code in the payload. This code is defined in
0
0
0
ANSI T1.403-1995 as a 00110010 11111111 pattern in the
facility data link (received right-to-left). This signal is set when
the pattern is detected (10 consecutive times) and is cleared
when it is read if the pattern is no longer being detected.
FRM_FDL_LLBON ESF_FDL Line Loopback Enable. A 1 indicates the receive
framer detected the ESF_FDL line loopback enable code in
the payload. This code is defined in ANSI T1.403-1995 as a
00001110 11111111 pattern in the facility data link (received
right-to-left). This signal is set when the pattern is detected
(10 consecutive times) and is cleared when it is read if the pat-
tern is no longer being detected.
FRM_FDL_LLBOFF ESF_FDL Line Loopback Disable. A 1 indicates the receive
framer detected the ESF_FDL line loopback disable code in
the payload. This code is defined in ANSI T1.403-1995 as a
00111000 11111111 pattern in the facility data link (received
right-to-left). This signal is set when the pattern is detected
(10 consecutive times) and is cleared when it is read if the pat-
tern is no longer being detected.
* See Table 393 on page 279 for values of L and P.
Table 400. FRM_PMLR7, Performance Monitor Link Register 7 (COR)
Address* Bit
Name
Function
Reset
Default
0x8LP86 15:0
FRM_BPV[15:0]
Bipolar Violation Counter. This register contains the 16-bit
count of received bipolar violations, line code violations, and
excessive zeros.
0x0
* See Table 393 on page 279 for values of L and P.
Agere Systems Inc.
289