 浏览型号HD6433846XXXH的Datasheet PDF文件第292页浏览型号HD6433846XXXH的Datasheet PDF文件第293页浏览型号HD6433846XXXH的Datasheet PDF文件第294页浏览型号HD6433846XXXH的Datasheet PDF文件第295页浏览型号HD6433846XXXH的Datasheet PDF文件第297页浏览型号HD6433846XXXH的Datasheet PDF文件第298页浏览型号HD6433846XXXH的Datasheet PDF文件第299页浏览型号HD6433846XXXH的Datasheet PDF文件第300页  
Bit 4: Framing error (FER)  
Bit 4 indicates that a framing error has occurred during reception in asynchronous mode.  
Bit 4  
FER  
Description  
0
Reception in progress or completed*1  
Clearing conditions:  
(initial value)  
After reading FER = 1, cleared by writing 0 to FER  
1
A framing error has occurred during reception  
Setting conditions:  
When the stop bit at the end of the receive data is checked for a value  
of 1 at the end of reception, and the stop bit is 0*2  
Notes: 1. When bit RE in SCR3 is cleared to 0, bit FER is not affected and retains its previous  
state.  
2. Note that, in 2-stop-bit mode, only the first stop bit is checked for a value of 1, and the  
second stop bit is not checked. When a framing error occurs the receive data is  
transferred to RDR but bit RDRF is not set. Reception cannot be continued with bit  
FER set to 1. In synchronous mode, neither transmission nor reception is possible  
when bit FER is set to 1.  
Bit 3: Parity error (PER)  
Bit 3 indicates that a parity error has occurred during reception with parity added in asynchronous  
mode.  
Bit 3  
PER  
Description  
0
Reception in progress or completed*1  
Clearing conditions:  
(initial value)  
After reading PER = 1, cleared by writing 0 to PER  
1
A parity error has occurred during reception*2  
Setting conditions:  
When the number of 1 bits in the receive data plus parity bit does not  
match the parity designated by bit PM in the serial mode register  
(SMR)  
Notes: 1. When bit RE in SCR3 is cleared to 0, bit PER is not affected and retains its previous  
state.  
2. Receive data in which it a parity error has occurred is still transferred to RDR, but bit  
RDRF is not set. Reception cannot be continued with bit PER set to 1. In synchronous  
mode, neither transmission nor reception is possible when bit FER is set to 1.  
281  
 复制成功!