欢迎访问ic37.com |
会员登录 免费注册
发布采购

XC3S1600E-4FGG320C 参数 Datasheet PDF下载

XC3S1600E-4FGG320C图片预览
型号: XC3S1600E-4FGG320C
PDF下载: 下载PDF文件 查看货源
内容描述: 的Spartan- 3E FPGA系列 [Spartan-3E FPGA Family]
分类和应用: 现场可编程门阵列可编程逻辑时钟
文件页数/大小: 193 页 / 1733 K
品牌: XILINX [ XILINX, INC ]
 浏览型号XC3S1600E-4FGG320C的Datasheet PDF文件第41页浏览型号XC3S1600E-4FGG320C的Datasheet PDF文件第42页浏览型号XC3S1600E-4FGG320C的Datasheet PDF文件第43页浏览型号XC3S1600E-4FGG320C的Datasheet PDF文件第44页浏览型号XC3S1600E-4FGG320C的Datasheet PDF文件第46页浏览型号XC3S1600E-4FGG320C的Datasheet PDF文件第47页浏览型号XC3S1600E-4FGG320C的Datasheet PDF文件第48页浏览型号XC3S1600E-4FGG320C的Datasheet PDF文件第49页  
R
Functional Description  
Table 24 defines each port of the MULT18X18SIO primitive.  
Table 24: MULT18X18SIO Embedded Multiplier Primitives Description  
Signal Name  
A[17:0]  
Direction  
Input  
Function  
The primary 18-bit two’s complement value for multiplication. The block multiplies by  
this value asynchronously if the optional AREG and PREG registers are omitted.  
When AREG and/or PREG are used, the value provided on this port is qualified by  
the rising edge of CLK, subject to the appropriate register controls.  
B[17:0]  
Input  
The second 18-bit two’s complement value for multiplication if the B_INPUT attribute  
is set to DIRECT. The block multiplies by this value asynchronously if the optional  
BREG and PREG registers are omitted. When BREG and/or PREG are used, the  
value provided on this port is qualified by the rising edge of CLK, subject to the  
appropriate register controls.  
BCIN[17:0]  
P[35:0]  
Input  
The second 18-bit two’s complement value for multiplication if the B_INPUT attribute  
is set to CASCADE. The block multiplies by this value asynchronously if the optional  
BREG and PREG registers are omitted. When BREG and/or PREG are used, the  
value provided on this port is qualified by the rising edge of CLK, subject to the  
appropriate register controls.  
Output  
The 36-bit two’s complement product resulting from the multiplication of the two input  
values applied to the multiplier. If the optional AREG, BREG and PREG registers are  
omitted, the output operates asynchronously. Use of PREG causes this output to  
respond to the rising edge of CLK with the value qualified by CEP and RSTP. If PREG  
is omitted, but AREG and BREG are used, this output responds to the rising edge of  
CLK with the value qualified by CEA, RSTA, CEB, and RSTB. If PREG is omitted and  
only one of AREG or BREG is used, this output responds to both asynchronous and  
synchronous events.  
BCOUT[17:0]  
Output  
Input  
The value being applied to the second input of the multiplier. When the optional  
BREG register is omitted, this output responds asynchronously in response to  
changes at the B[17:0] or BCIN[17:0] ports according to the setting of the B_INPUT  
attribute. If BREG is used, this output responds to the rising edge of CLK with the  
value qualified by CEB and RSTB.  
CEA  
Clock enable qualifier for the optional AREG register. The value provided on the  
A[17:0] port is captured by AREG in response to a rising edge of CLK when this  
signal is High, provided that RSTA is Low.  
RSTA  
CEB  
Input  
Input  
Synchronous reset for the optional AREG register. AREG content is forced to the  
value zero in response to a rising edge of CLK when this signal is High.  
Clock enable qualifier for the optional BREG register. The value provided on the  
B[17:0] or BCIN[17:0] port is captured by BREG in response to a rising edge of CLK  
when this signal is High, provided that RSTB is Low.  
RSTB  
CEP  
Input  
Input  
Synchronous reset for the optional BREG register. BREG content is forced to the  
value zero in response to a rising edge of CLK when this signal is High.  
Clock enable qualifier for the optional PREG register. The value provided on the  
output of the multiplier port is captured by PREG in response to a rising edge of CLK  
when this signal is High, provided that RSTP is Low.  
RSTP  
Input  
Synchronous reset for the optional PREG register. PREG content is forced to the  
value zero in response to a rising edge of CLK when this signal is High.  
Notes:  
1. The control signals CLK, CEA, RSTA, CEB, RSTB, CEP, and RSTP have the option of inverted polarity.  
38  
www.xilinx.com  
DS312-2 (v1.1) March 21, 2005  
Advance Product Specification  
 复制成功!