欢迎访问ic37.com |
会员登录 免费注册
发布采购

WM8776_05 参数 Datasheet PDF下载

WM8776_05图片预览
型号: WM8776_05
PDF下载: 下载PDF文件 查看货源
内容描述: 24位, 192kHz立体声编解码器与5频道I / P多路复用器 [24-bit, 192kHz Stereo CODEC with 5 Channel I/P Multiplexer]
分类和应用: 解码器复用器编解码器
文件页数/大小: 57 页 / 601 K
品牌: WOLFSON [ WOLFSON MICROELECTRONICS PLC ]
 浏览型号WM8776_05的Datasheet PDF文件第31页浏览型号WM8776_05的Datasheet PDF文件第32页浏览型号WM8776_05的Datasheet PDF文件第33页浏览型号WM8776_05的Datasheet PDF文件第34页浏览型号WM8776_05的Datasheet PDF文件第36页浏览型号WM8776_05的Datasheet PDF文件第37页浏览型号WM8776_05的Datasheet PDF文件第38页浏览型号WM8776_05的Datasheet PDF文件第39页  
Production Data  
WM8776  
The gain control circuit is enabled by setting the LCEN control bit. The user can select between  
Limiter mode and three different ALC modes using the LCSEL control bits.  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
R17 (11h)  
0010001  
8
LCEN  
0
Enable the PGA gain control circuit.  
0 = Disabled  
ALC Control 2  
R16 (10h)  
1 = Enabled  
8:7  
LCSEL  
00  
LC function select  
0010000  
00 = Limiter  
ALC Control 1  
01 = ALC Right channel only  
10 = ALC Left channel only  
11 = ALC Stereo  
The limiter function only operates in stereo, which means that the peak detector takes the maximum  
of left and right channel peak values, and any new gain setting is applied to both left and right PGAs,  
so that the stereo image is preserved. However, the ALC function can also be enabled on one  
channel only. In this case, only one PGA is controlled by the ALC mechanism, while the other  
channel runs independently with its PGA gain set through the control register.  
When enabled, the threshold for the limiter or target level for the ALC is programmed using the LCT  
control bits. This allows the threshold/target level to be programmed between -1dB and -16dB in 1dB  
steps.  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
R16 (10h)  
0010000  
3:0  
LCT[3:0]  
1011  
Limiter Threshold/ALC target level in  
1dB steps.  
(-5dB)  
0000: -16dB FS  
0001: -15dB FS  
ALC Control 1  
1101: -3dB FS  
1110: -2dB FS  
1111: -1dB FS  
ATTACK AND DECAY TIMES  
The limiter and ALC have different attack and decay times which determine their operation. However,  
the attack and decay times are defined slightly differently for the limiter and for the ALC. DCY and  
ATK control the decay and attack times, respectively.  
Decay time (Gain Ramp-Up). When in ALC mode, this is defined as the time that it takes for the  
PGA gain to ramp up across 90% of its range (e.g. from –21dB up to +20 dB). When in limiter mode,  
it is defined as the time it takes for the gain to ramp up by 6dB.  
The decay time can be programmed in power-of-two (2n) steps. For the ALC this gives times from  
33.6ms, 67.2ms, 134.4ms etc. to 34.41s. For the limiter this gives times from 1.2ms, 2.4ms etc., up  
to 1.2288s.  
Attack time (Gain Ramp-Down) When in ALC mode, this is defined as the time that it takes for the  
PGA gain to ramp down across 90% of its range (e.g. from +20dB down to -21dB gain). When in  
limiter mode, it is defined as the time it takes for the gain to ramp down by 6dB.  
The attack time can be programmed in power-of-two (2n) steps, from 8.4ms, 16.8ms, 33.6ms etc. to  
8.6s for the ALC and from 250us, 500us, etc. up to 256ms.  
The time it takes for the recording level to return to its target value or static gain value therefore  
depends on both the attack/decay time and on the gain adjustment required. If the gain adjustment is  
small, it will be shorter than the attack/decay time.  
PD Rev 4.0 April 2005  
35  
w
 复制成功!