欢迎访问ic37.com |
会员登录 免费注册
发布采购

WM8352 参数 Datasheet PDF下载

WM8352图片预览
型号: WM8352
PDF下载: 下载PDF文件 查看货源
内容描述: 欧胜音频Plusa ? ¢立体声CODEC与电源管理 [Wolfson AudioPlus™ Stereo CODEC with Power Management]
分类和应用:
文件页数/大小: 336 页 / 2353 K
品牌: WOLFSON [ WOLFSON MICROELECTRONICS PLC ]
 浏览型号WM8352的Datasheet PDF文件第290页浏览型号WM8352的Datasheet PDF文件第291页浏览型号WM8352的Datasheet PDF文件第292页浏览型号WM8352的Datasheet PDF文件第293页浏览型号WM8352的Datasheet PDF文件第295页浏览型号WM8352的Datasheet PDF文件第296页浏览型号WM8352的Datasheet PDF文件第297页浏览型号WM8352的Datasheet PDF文件第298页  
WM8352  
Production Data  
REFER TO  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
mask.  
Register B3h Power-check comparator  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
REFER TO  
R180 (B4h)  
DCDC1  
Control  
15:14  
DC1_CAP[1:0]  
00  
DC-DC1 Output Capacitor  
00 = 10uF, 30uF, 45uF  
01 = 60uF, 85uF  
10 = Not used  
11 = 100uF  
Reset by state machine.  
Over voltage Protection  
0 = enabled  
11  
DC1_DISOVP  
DC1_OPFLT  
0
0
1 = disabled  
Reset by state machine. Default held in metal mask.  
10  
Enable discharge of DC-DC1 outputs when DC-DC1  
is disabled  
0 = Enabled - Output to be discharged  
1 = Disabled - Output is left floating  
DC-DC1 Converter output voltage settings in 25mV  
steps.  
Maximum output = 3.4V.  
6:0  
DC1_VSEL[6:0] 000_1110  
110_0010  
000_1110  
000_0110  
110 0110 = 3.4V  
110 0010 = 3.3V  
101 0110 = 3.0V  
100 1110 = 2.8V  
……  
010 0110 = 1.8V  
000 1110 = 1.2V  
000 0110 = 1.0V  
000 0000 = 0.85V  
Reset by state machine. Default held in metal mask.  
Register B4h DCDC1 Control  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
REFER TO  
Action to take on DC-DC1 fault (as well as  
generating an interrupt):  
R181 (B5h)  
DCDC1  
15:14 DC1_ERRACT[1:0]  
00  
Timeouts  
00 = ignore  
01 = shut down converter  
10 = shut down system  
11 = reserved (shut down system)  
Reset by state machine. Default held in metal  
mask.  
Time slot for DC-DC1 start-up  
0000 = Disabled (do not start up)  
0001 = Start-up in time slot 1  
… (total 14 slots available)  
13:10 DC1_ENSLOT[3:0]  
0000  
0001  
0010  
0001  
1110 = Start-up in time slot 14  
1111 = Start-up on entering ACTIVE  
Reset by state machine. Default held in metal  
mask.  
Time slot for DC-DC1 shutdown.  
0000 = Shut down on entering OFF  
9:6  
DC1_SDSLOT[3:0]  
0000  
PD, February 2011, Rev 4.4  
294  
w
 复制成功!