Production Data  
WM8352  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
Limit Switch enable  
REFER TO  
R176 (B0h)  
DCDC/LDO  
requested  
15  
LS_ENA  
0
0 = disabled  
1 = enabled  
Note: internal conditions may prevent the converter  
from actually switching on - see DCDC/LDO Status  
register for actual converter status.  
Reset by state machine. Default held in metal mask.  
11  
10  
9
LDO4_ENA  
LDO3_ENA  
LDO2_ENA  
LDO1_ENA  
DC6_ENA  
DC5_ENA  
DC4_ENA  
0
0
0
0
0
0
0
LDO4 enable  
0 = disabled  
1 = enabled  
Note: internal conditions may prevent the converter  
from actually switching on - see DCDC/LDO Status  
register for actual converter status.  
Reset by state machine. Default held in metal mask.  
LDO3 enable  
0 = disabled  
1 = enabled  
Note: internal conditions may prevent the converter  
from actually switching on - see DCDC/LDO Status  
register for actual converter status.  
Reset by state machine. Default held in metal mask.  
LDO2 enable  
0 = disabled  
1 = enabled  
Note: internal conditions may prevent the converter  
from actually switching on - see DCDC/LDO Status  
register for actual converter status.  
Reset by state machine. Default held in metal mask.  
8
LDO1 enable  
0 = disabled  
1 = enabled  
Note: internal conditions may prevent the converter  
from actually switching on - see DCDC/LDO Status  
register for actual converter status.  
Reset by state machine. Default held in metal mask.  
DCDC6 converter enable  
0 = disabled  
5
1 = enabled  
Note: internal conditions may prevent the converter  
from actually switching on - see DCDC/LDO Status  
register for actual converter status.  
Reset by state machine. Default held in metal mask.  
DCDC5 converter enable  
0 = disabled  
4
1 = enabled  
Note: internal conditions may prevent the converter  
from actually switching on - see DCDC/LDO Status  
register for actual converter status.  
Reset by state machine. Default held in metal mask.  
DCDC4 converter enable  
0 = disabled  
3
1 = enabled  
Note: internal conditions may prevent the converter  
from actually switching on - see DCDC/LDO Status  
register for actual converter status.  
PD, February 2011, Rev 4.4  