WM8352  
Production Data  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
REFER TO  
R187 (BBh)  
DCDC3  
15:14 DC3_ERRACT[1:0]  
00  
Action to take on DC-DC3 fault (as well as  
generating an interrupt):  
Timeouts  
00 = ignore  
01 = shut down converter  
10 = shut down system  
11 = reserved (shut down system)  
Reset by state machine. Default held in metal  
mask.  
13:10 DC3_ENSLOT[3:0]  
0000  
0010  
0110  
0011  
Time slot for DC-DC3 start-up  
0000 = Disabled (do not start up)  
0001 = Start-up in time slot 1  
… (total 14 slots available)  
1110 = Start-up in time slot 14  
1111 = Start-up on entering ACTIVE  
Reset by state machine. Default held in metal  
mask.  
9:6  
DC3_SDSLOT[3:0]  
0000  
Time slot for DC-DC3 shutdown.  
0000 = Shut down on entering OFF  
0001 = Shutdown in time slot 1  
…. (total 14 slots available)  
1110 = Shutdown in time slot 14  
1111 = Shut down on entering OFF  
Register BBh DCDC3 Timeouts  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
REFER TO  
R188 (BCh) 14:12 DC3_HIB_MODE[2:0]  
000  
DC-DC3 Hibernate behaviour:  
DCDC3 Low  
Power  
000 = Use current settings (no change)  
001 = Select voltage image settings  
010 = Force standby mode  
011 = Force standby mode and voltage image  
settings.  
100 = Force LDO mode  
101 = Force LDO mode and voltage image  
settings.  
110 = Reserved.  
111 = Disable output  
Reset by state machine. Default held in metal  
mask.  
9:8  
DC3_HIB_TRIG[1:0]  
00  
DC-DC3 Hibernate signal select  
00 = HIBERNATE register bit  
01 = L_PWR1  
10 = L_PWR2  
11 = L_PWR3  
Note that Hibernate is also selected when a  
GPIO Hibernate input is asserted.  
Reset by state machine. Default held in metal  
mask.  
PD, February 2011, Rev 4.4  