WM8352  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
REFER TO  
R184 (B8h)  
DCDC2  
15:14 DC2_ERRACT[1:0]  
00  
Action to take on DC-DC2 fault (as well as  
generating an interrupt):  
Timeouts  
00 = ignore  
01 = shut down converter  
10 = shut down system  
11 = reserved (shut down system)  
Reset by state machine. Default held in metal  
mask.  
13:10 DC2_ENSLOT[3:0]  
0000  
Time slot for DC-DC2 start-up  
0000 = Disabled (do not start up)  
0001 = Start-up in time slot 1  
… (total 14 slots available)  
1110 = Start-up in time slot 14  
1111 = Start-up on entering ACTIVE  
Reset by state machine. Default held in metal  
mask.  
9:6  
DC2_SDSLOT[3:0]  
0000  
Time slot for DC-DC2 shutdown.  
0000 = Shut down on entering OFF  
0001 = Shutdown in time slot 1  
…. (total 14 slots available)  
1110 = Shutdown in time slot 14  
1111 = Shut down on entering OFF  
Register B8h DCDC2 Timeouts  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
REFER TO  
R186 (BAh)  
DCDC3  
Control  
11  
DC3_DISOVP  
0
Over voltage Protection  
0 = enabled  
1 = disabled  
Reset by state machine. Default held in metal mask.  
10  
DC3_OPFLT  
0
Enable discharge of DC-DC3 outputs when DC-DC3  
is disabled  
0 = Enabled - Output to be discharged  
1 = Disabled - Output is left floating  
6:0  
DC3_VSEL[6:0] 000_0000 DC-DC3 Converter output voltage settings in 25mV  
steps.  
000_0110  
101_0110  
101_0000  
Maximum output = 3.4V.  
110 0110 = 3.4V  
110 0010 = 3.3V  
101 0110 = 3.0V  
100 1110 = 2.8V  
……  
010 0110 = 1.8V  
000 1110 = 1.2V  
000 0110 = 1.0V  
000 0000 = 0.85V  
Reset by state machine. Default held in metal mask.  
Register BAh DCDC3 Control  
PD, February 2011, Rev 4.4  
297  
w
 复制成功!