WM8352  
Production Data  
DESCRIPTION  
ADDRESS  
BIT  
LABEL  
DEFAULT  
R183 (B7h) for  
DC-DC2  
12  
DCn_HIB_MO  
DE  
0
DC-DCn Hibernate behaviour:  
0 = Continue as in Active state  
1 = Disable converter output  
DC-DCn Hibernate signal select  
00 = HIBERNATE register bit  
01 = L_PWR1  
R192 (C0h) for  
DC-DC5  
9:8  
DCn_HIB_TRI  
G [1:0]  
00  
10 = L_PWR2  
11 = L_PWR3  
Note that Hibernate is also selected  
when a GPIO Hibernate input is  
asserted.  
Note: n is either 2 or 5 and identifies the individual DC-DC converter  
Table 78 Hibernate Mode Control for DC-DC Converters 2 and 5  
14.6.5 INTERRUPTS AND FAULT PROTECTION  
Each DC-DC Converter is monitored for voltage accuracy and fault conditions. An undervoltage  
condition is set if the voltage falls below 95% of the required level. The action taken in response to a  
fault condition can be set independently for each DC-DC Converter, as described in Table 79.  
The DCn_ERRACT fields configure the fault response to disable the respective converter or to shut  
down the entire system if desired. In addition, DC-DC Converter fault conditions also generate a  
second-level interrupt (see Section 24).  
To prevent false alarms during short current surges, faults are only signalled if the fault condition  
persists. When a DC-DC Converter is started up, any initial fault condition is ignored until the  
Converter has been allowed time to settle. The time for which any fault condition is ignored is set by  
the PUTO register field, as described in Table 79.  
ADDRESS  
R181 (B5h) for  
DC-DC1  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
15:14  
DCn_ERRAC  
T [1:0]  
00  
Action to take on DC-DCn fault (as well  
as generating an interrupt):  
00 = ignore  
01 = shut down converter  
10 = shut down system  
11 = reserved (shut down system)  
R184 (B8h) for  
DC-DC2  
R187 (BBh) for  
DC-DC3  
R190 (BEh) for  
DC-DC4  
R193 (C1h) for  
DC-DC5  
R196 (C4h) for  
DC-DC6  
R177 (B1h)  
DCDC Active  
options  
13:12  
PUTO [1:0]  
00  
Power up time out value for all  
converters  
00 = 0.5ms  
01 = 2ms  
10 = 32ms  
11 = 256ms  
Note: n is a number between 1 and 6 that identifies the individual DC-DC converter  
Table 79 Fault Responses for DC-DC Converters  
PD, February 2011, Rev 4.4  
132  