W83697HF/F
Bank 1
9.7.31 Temperature Sensor 2 Configuration Register - Index 52h (
)
Register Location:
Power on Default Value
Size:
52h
00h
8 bits
7
6
5
4
3
2
1
0
STOP2
INTMOD
Reserved
FAULT
FAULT
Reserved
Reserved
Reserved
Bit 7-5: Read - Reserved. This bit should be set to 0.
Bit 4-3: Read/Write - Number of faults to detect before setting OVT# output to avoid false tripping due
to noise.
Bit 2: Read - Reserved. This bit should be set to 0.
Bit 1: Read/Write - OVT# Interrupt mode select. This bit default is set to 0, which is compared mode.
When set to 1, interrupt mode will be selected.
Bit 0: Read/Write - When set to 1 the sensor will stop monitor.
Bank 1
9.7.32 Temperature Sensor 2 Hysteresis (High Byte) Register - Index 53h (
)
Register Location:
Power on Default Value
Attribute:
53h
4Bh
Read/Write
8 bits
Size:
7
6
5
4
3
2
1
0
THYST2<8:1>
Bit 7-0: Temperature hysteresis bit 8-1, which is High Byte. The temperature default 75 degree C.
Publication Release Date: Feb. 2002
- 117 -
Revision 0.70