欢迎访问ic37.com |
会员登录 免费注册
发布采购

BCM3814B60E10A5C02 参数 Datasheet PDF下载

BCM3814B60E10A5C02图片预览
型号: BCM3814B60E10A5C02
PDF下载: 下载PDF文件 查看货源
内容描述: [Isolated Fixed-Ratio DC-DC Converter]
分类和应用:
文件页数/大小: 39 页 / 1258 K
品牌: VICOR [ VICOR CORPORATION ]
 浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第28页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第29页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第30页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第31页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第33页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第34页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第35页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第36页  
BCM3814x60E10A5yzz  
READ_VIN Command (88h)  
READ_POUT Command (96h)  
If PAGE data byte is equal to (01h - 04h) command will return a  
reported individual BCM’s HI side voltage in the following format:  
If PAGE data byte is equal to (01h - 04h) command will return a  
reported individual BCM’s LO side power in the following format:  
VHI_ACTUAL = VHI_REPORTED • 10-1(V)  
PLO_ACTUAL = PLO_REPORTED (W)  
READ_IIN Command (89h)  
If PAGE data byte is equal to (00h) command will return the sum of  
active BCM’s LO side power.  
If PAGE data byte is equal to (01h - 04h) command will return a  
reported individual BCM’s HI side current in the following format:  
MFR_VIN_MIN Command (A0h),  
MFR_VIN_MAX Command (A1h),  
MFR_VOUT_MIN Command (A4h),  
MFR_VOUT_MAX Command (A5h),  
MFR_IOUT_MAX Command (A6h),  
MFR_POUT_MAX Command (A7h)  
IHI_ACTUAL = IHI_REPORTED • 10-2(A)  
If PAGE data byte is equal (00h) command will return the sum of  
active BCM’s HI side current.  
READ_VOUT Command (8Bh)  
These values are set by the factory and indicate the device HI side/  
LO side voltage and LO side current range and LO side power  
capacity.  
If PAGE data byte is equal to (01h - 04h) command will return a  
reported individual BCM’s LO side voltage in the following format:  
The internal µC will report rated BCM HI side voltage minimum  
and maximum in Volts, LO side voltage minimum and maximum  
in Volts, LO side current maximum in Amperes and LO side power  
maximum in Watts.  
VLO_ACTUAL = VLO_REPORTED • 10-1(V)  
READ_IOUT Command (8Ch)  
If PAGE data byte is equal to (00h) then:  
If PAGE data byte is equal to (01h - 04h) command will return a  
reported individual BCM’s LO side current in the following format:  
n MFR_VIN_MIN COMMAND (A0h) will return the highest  
MFR_VIN_MIN of all active BCMs  
n MFR_VIN_MAX COMMAND (A1h) will return the lowest  
MFR_VIN_MAX of all active BCMs  
ILO_ACTUAL = ILO_REPORTED • 10-2(A)  
n MFR_VOUT_MIN COMMAND (A4h) will return the highest  
If PAGE data byte is equal (00h) command will return the sum of  
active BCM’s LO side current.  
MFR_VOUT_MIN of all active BCMs  
n MFR_VOUT_MAX COMMAND (A5h) will return the lowest  
MFR_VOUT_MAX of all active BCMs  
READ_TEMPERATURE_1 Command (8Dh)  
n MFR_IOUT_MAX COMMAND (A6h) will return the SUM of  
MFR_IOUT_MAX of all active BCMs  
If PAGE data byte is equal to (01h - 04h) command will return a  
reported individual BCM’s temperature in the following format:  
n MFR_POUT_MAX COMMAND (A7h) will return the SUM of  
MFR_POUT_MAX of all active BCMs  
TACTUAL = TREPORTED (°C)  
If PAGE data byte is equal (00h) command will return the maximum  
temperature of active BCM’s.  
BCM® in a VIA Package  
Page 32 of 39  
Rev 1.4  
09/2016  
vicorpower.com  
800 927.9474  
 复制成功!