BCM3814x60E10A5yzz
Supported Commands Transaction Type
Page Command (00h)
A direct communication to the BCM internal µC and a simulated
communication to non-PMBus™ devices is enabled by a page
command. Supported command access privileges with a pre-
selected PAGE are defined in the following table. Deviation from
this table generates a communication error in
The page command data byte of 00h prior to a command call will
address the internal µC specific data and a page data byte of FFh
would broadcast to all of the connected BCMs. The value of the
Data Byte corresponds to the pin name trailing number with the
exception of 00h and FFh.
STATUS_CML register.
Data Byte
Description
PAGE Data Byte
Access Type
00h
01h
µC
Command
Code
BCM
00h
01h
PAGE
00h
01h
02h
03h
19h
4Fh
R/W
R
R/W
R/W
R
OPERATION Command (01h)
OPERATION
ON_OFF_CONFIG
CLEAR_FAULTS
CAPABILITY
The Operation command can be used to turn on and off the
connected BCM. Note that the host OPERATION command will not
enable the BCM if the BCM EN pin is disabled in hardware with
respect to the pre set pin polarity. Only with the EN pin active, will
the OPERATION command provide ON/OFF control.
W
R
W
OT_FAULT_LIMIT
OT_WARN_LIMIT
VIN_OV_FAULT_LIMIT
VIN_OV_WARN_LIMIT
IIN_OC_FAULT_LIMIT
IIN_OC_WARN_LIMIT
TON_DELAY
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
51h
55h
57h
5Bh
5Dh
60h
78h
79h
7Bh
7Ch
7Dh
7Eh
80h
88h
89h
8Bh
8Ch
8Dh
96h
98h
99h
9Ah
9Bh
9Ch
9Dh
9Eh
A0h
A1h
A4h
A5h
A6h
A7h
D0h
D1h
D4h
D5h
D7h
If synchronous startup is required in the system, it is recommended
to use the command from host PMBus in order to achieve
simultaneous array startup.
STATUS_BYTE
R/W
R
STATUS_WORD
STATUS_IOUT
R
Unit is On when asserted (default)
Reserved
R
R/W
R/W
R/W
STATUS_INPUT
STATUS_TEMPERATURE
STATUS_CML
R
R
R/W
R
7
6
5
4
3
2
1
0
STATUS_MFR_SPECIFIC
READ_VIN
R/W
R
b
1
0
0
0
0
0
0
0
READ_IIN
R
R
READ_VOUT
R
This command accepts only two data values: 00h and 80h. If any
other value is sent the command will be rejected and a CML Data
error will result.
READ_IOUT
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
READ_TEMPERATURE_1
READ_POUT
R
R
PMBUS_REVISION
MFR_ID
MFR_MODEL
R
R
MFR_REVISION
MFR_LOCATION
MFR_DATE
R
R
MFR_SERIAL
R
MFR_VIN_MIN
R
MFR_VIN_MAX
MFR_VOUT_MIN
MFR_VOUT_MAX
MFR_IOUT_MAX
MFR_POUT_MAX
BCM_EN_POLARITY
READ_K_FACTOR
READ_BCM_ROUT
SET_ALL_THRESHOLDS
DISABLE_FAULT
R
R
R
R
R
R/W
R
R
R/W
R/W
BCM® in a VIA Package
Page 28 of 39
Rev 1.4
09/2016
vicorpower.com
800 927.9474