 浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第26页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第27页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第28页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第29页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第31页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第32页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第33页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第34页  
BCM3814x60E10A5yzz  
STATUS_BYTE (78h) and STATUS_WORD (79h)  
STATUS_WORD  
High Byte  
Low Byte  
STATUS_BYTE  
Not Supported: UNKNOWN FAULT OR WARNING  
Not Supported: OTHER  
UNIT IS BUSY  
UNIT IS OFF  
Not Supported: FAN FAULT OR WARNING  
Not Supported: VOUT_OV_FAULT  
POWER_GOOD Negated*  
IOUT_OC_FAULT  
VIN_UV_FAULT  
STATUS_MFR_SPECIFIC  
INPUT FAULT OR WARNING  
TEMPERATURE FAULT OR WARNING  
IOUT/POUT FAULT OR WARNING  
PMBusTM COMMUNCATION EVENT  
NONE OF THE ABOVE  
Not Supported: VOUT FAULT OR WARNING  
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
0
1
1
1
1
0
0
0
1
1
0
1
1
1
1
0
b
* equal to POWER_GOOD#  
If the internal µC is still powered, it will retain the last status it  
received from the BCM and this information will be available to  
the user via a PMBus Status request. This is in agreement with the  
PMBus standard which requires that status bits remain set until  
specifically cleared. Note that in this case where the BCM VHI is lost,  
the status will always indicate an under voltage fault, in addition to  
any other fault  
All fault or warning flags, if set, will remain asserted until  
cleared by the host or once the internal µC power is removed.  
This includes under voltage fault, overvoltage fault, overvoltage  
warning, overcurrent warning, over temperature fault, over  
temperature warning, under temperature fault, reverse operation,  
communication faults and analog controller shutdown fault.  
that occurred.  
Asserted status bits in all status registers, with the exception of  
STATUS_WORD and STATUS_BYTE, can be individually cleared.  
This is done by sending a data byte with one in the bit position  
corresponding to the intended warning or fault to be cleared. Refer  
to the PMBus™ Power System Management Protocol Specification  
– Part II – Revision 1.2 for details.  
NONE OF THE ABOVE bit will be asserted if either the STATUS_  
MFR_SPECIFIC (80h) or the High Byte of the STATUS WORD  
is set.  
STATUS_IOUT (7Bh)  
The POWER_GOOD# bit reflects the state of the device and does  
not reflect the state of the POWER_GOOD# signal limits. The  
POWER_GOOD_ON COMMAND (5Eh) and POWER_GOOD_OFF  
COMMAND (5Fh) are not supported. The POWER_GOOD# bit is  
set anytime the BCM is not in the enabled state, to indicate that  
the powertrain is inactive and not switching. The POWER_GOOD#  
bit is cleared when the BCM completes the enabling state, 5 ms  
after the powertrain is activated allowing for soft start to elapse.  
POWER_GOOD# and OFF bits cannot be cleared as they always  
reflect the current state of the device.  
IOUT_OC_FAULT  
Not Supported: IOUT_OC_LV_FAULT  
IOUT_OC_WARNING  
Not Supported: IOUT_UC_FAULT  
Not Supported: Current Share Fault  
Not Supported: In Power Limiting Mode  
Not Supported: POUT_OP_FAULT  
Not Supported: POUT_OP_WARNING  
When Page (00h) is used the POWER_GOOD# bit reflects the OR-  
ing of all active BCMs’ POWER_GOOD# bits. When Page  
(01h – 04h) is used POWER_GOOD# is clear only when the  
BCM is active.  
7
6
5
4
3
2
1
0
When Page (00h) is used UNIT IS OFF is SET when all BCMs are  
not active. When Page (01h – 04h) is used UNIT IS OFF is clear only  
when the BCM is active.  
b
1
0
0
1
0
0
0
0
Unsupported bits are indicated above. A one indicates a fault.  
The Busy bit can be cleared using CLEAR_ALL Command (03h) or  
by writing either data value (40h, 80h) to PAGE (00h) using the  
STATUS_BYTE (78h).  
Fault reporting, such as SMBALERT# signal output, and host  
notification by temporarily acquiring bus master status is  
not supported.  
BCM® in a VIA Package  
Page 30 of 39  
Rev 1.4  
09/2016  
vicorpower.com  
800 927.9474  