 浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第29页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第30页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第31页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第32页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第34页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第35页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第36页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第37页  
BCM3814x60E10A5yzz  
BCM_EN_POLARITY Command (D0h)  
SET_ALL_THRESHOLDS Command (D5h)  
Reserved  
Reserved  
Reserved  
SET_ALL_THRESHOLDS_BLOCK (6 Bytes)  
IOUT_OC_WARN_ LIMIT  
IOUT_OC_FAULT_ LIMIT  
Reserved  
VIN_OV_WARN_ LIMIT  
Reserved  
VIN_OV_FAULT_ LIMIT  
OT_WARN_LIMIT  
Reserved  
BCM EN Pin Polarity  
Reserved  
OT_FAULT_LIMIT  
5
4
3
2
1
0
7
6
5
4
3
2
1
0
h
64 64 64 64 64 64  
b
0
0
0
0
0
0
1
0
Values of this register block is set in non volatile memory and can  
only be written when the BCMs are disabled.  
The value of this register is set in non volatile memory and can only  
be written when the BCMs are disabled.  
This command provides a convenient way to configure all the  
limits, or any combination of limits described previously using one  
command.  
When PAGE COMMAND (00h) data byte is equal to (01h – 04h),  
this command defines the polarity of the EN pin. If BCM_EN_  
POLARITY is set, the BCM will startup once VHI is greater than the  
under voltage threshold.  
VHI Overvoltage, Overcurrent and Overtemperature values are all  
set to 100% of the BCM datasheet supervisory limits by default  
and can only be set to a lower percentage.  
The BCM EN PIN is internally pulled-up to 3.3V. If the BCM_EN_  
POLARITY is cleared, an external pull-down is then required.  
Applying VHI greater than the under voltage threshold will not  
suffice to start the BCM.  
To leave a particular threshold unchanged, set the corresponding  
threshold data byte to a value greater than (64h).  
READ_K_FACTOR Command (D1h)  
DISABLE_FAULT Command (D7h)  
If PAGE data byte is equal to (01h - 04h) command will return a  
reported individual BCMs K factor in the following format:  
DISABLE_FAULT  
MSB  
LSB  
K_FACTORACTUAL = K_FACTORREPORTED 2-16(V/V)  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
IOUT_OC_FAULT  
Reserved  
The K factor is defined in a BCM to represent the ratio of the  
transformer winding and hence is equal to VLO / VHI.  
VIN_OV_FAULT  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
VIN_UV_FAULT  
Reserved  
READ_BCM_ROUT Command (D4h)  
If PAGE data byte is equal to (01h - 04h) command will return  
a reported individual BCM’s LO side resistance in the following  
format:  
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
0
1
0
0
0
0
0
0
0
0
1
0
1
0
0
0
b
BCM_RLO_ACTUAL = BCM_RLO_REPORTED • 10-5(Ω)  
Unsupported bits are indicated above. A one indicates that the  
supervisory fault associated with the asserted bit is disabled.  
The value of these registers is set in non volatile memory and can  
only be written when the BCMs are disabled.  
This command allows the host to disable the supervisory faults  
and respective statuses. It does not disable the powertrain analog  
protections or warnings with respect to the set limits in the SET_  
ALL_THRESHOLDS Command.  
The HI side undervoltage can only be disabled to a pre set low limit  
as shown in the functional reporting range in the BCM data sheet.  
BCM® in a VIA Package  
Page 33 of 39  
Rev 1.4  
09/2016  
vicorpower.com  
800 927.9474  