 浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第25页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第26页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第27页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第28页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第30页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第31页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第32页浏览型号BCM3814B60E10A5C02的Datasheet PDF文件第33页  
BCM3814x60E10A5yzz  
ON_OFF_CONFIG Command (02h)  
OT_FAULT_LIMIT Command (4Fh),  
OT_WARN_ LIMIT Command (51h),  
VIN_OV_FAULT_ LIMIT Command (55h),  
VIN_OV_WARN_ LIMIT Command (57h),  
IIN_OC_FAULT_ LIMIT Command (5Bh),  
IIN_OC_WARN_ LIMIT Command (5Dh)  
Reserved for Future Use  
Unit does not power up until commanded by the  
CONTROL pin and operation command  
Unit requires that the on/off portion of the  
OPERATION command is instructing the unit to run[1]  
Unit requires the CONTROL pin to be asserted  
to start the unit[2]  
The values of these registers are set in non volatile memory and  
can only be written when the BCMs are disabled.  
Not supported: Polarity of the CONTROL pin[3]  
Turn off the output and stop transferring  
energy to the output as fast as possible[4]  
The values of the above mentioned fault and warning are set by  
default to a 100% of the respective BCM model supervisory limits.  
However these limits can be set to a lower value. For example: In  
order for a limit percentage to be set to 80% one would send a  
write command with a (50h) Data Word.  
7
6
5
4
3
2
1
0
b
0
0
0
1
1
1
0
1
Any values outside the range of (00h – 64h) sent by a host will be  
rejected, will not override the currently stored value and will set the  
Unsupported Data bit in STATUS_CML.  
[1] The BCM Enable pin is ALWAYS to be asserted for powerup. The  
BCM_EN_POLARITY command (D0h) bit[(1) defines the logic level  
required for the control pin (i.e BCM Enable pin) to be asserted.  
[2] With respect to the BCM EN Control Pin if used in system  
[3] See MFR_SPECIFIC_00 / BCM_EN_POLARITY to change the Polarity  
of the BCM Enable Pin  
The SET_ALL_THRESHOLDS COMMAND (D5h) combines in one  
block over temperature fault and warning limits, VHI overvoltage  
fault and warning limits as well as ILO overcurrent fault and warning  
limits. A delay prior to a read command of up to 200ms following a  
write of new value is required.  
[4] The BCM powertrain once disabled cannot sink current  
The VIN_UV_WARN_LIMIT (58h) and VIN_UV_FAULT_LIMIT  
(59h) are set by the factory and cannot be changed by the host.  
However, a host can disable the under voltage setting using the  
DISABLE_FAULT COMMAND (D7h).  
CLEAR_FAULTS Command (03h)  
This command clears all status bits that have been previously set.  
Persistent or active faults are re asserted again once cleared. All  
faults are latched once asserted in the internal µC. Registered faults  
will not be cleared when shutting down the BCM powertrain by  
recycling the BCM high side voltage, or toggling the BCM EN pin,  
or sending the OPERATION command.  
All FAULT_RESPONSE commands are unsupported. The BCM  
powertrain supervisory limits and powertrain protection will behave  
as described in the BCM datasheet. In general, once a fault is  
detected, the BCM powertrain will shut down and attempt to auto  
restart after a predetermined delay.  
CAPABILITY Command (19h)  
TON_DELAY Command (60h)  
Packet Error Checking is not supported  
Maximum supported bus speed is 400 KHz  
The value of this register word is set in non volatile memory and  
can only be written when the BCMs are disabled.  
The maximum possible delay is 100ms. Default value is set to (00h).  
Follow this equation below to interpret the reported value.  
The Device does not have SMBALERT# pin and does  
not support the SMBus Alert Response protocol  
Reserved  
TON_DELAYACTUAL = tREPORTED • 10-3(s)  
Staggering startup in an array is possible with TON_DELAY  
Command. This delay will be in addition to any startup delay  
inherent in the BCM module. For example: startup delay from  
application of VHI is typically 20ms whereas startup with EN pin is  
typically 250µs. When TON_DELAY is greater than zero, the set  
delay will be added to both.  
7
6
5
4
3
2
1
0
b
0
0
1
0
0
0
0
0
The internal µC returns a default value of 20h. This value indicates  
that the PMBus™ frequency supported is up to 400KHz and that  
both Packet Error Checking (PEC) and SMBALERT# are  
not supported.  
BCM® in a VIA Package  
Page 29 of 39  
Rev 1.4  
09/2016  
vicorpower.com  
800 927.9474  