7.20 MFC IO Emergency Switch Input  
The MFC IO block oers a dedicated emergency switch input called MFC_NES. It is low active.  
It is used to set specic MFCIOxx outputs to a a congurable safe state in case of emergency.  
The MFC_NES pin has weak internal pull-down resistor. A microcontroller or another circuit must actively  
drive a high level at MFC_NES for normal operation.  
The emergency switch input MFC_NES is only active if it is masked in the MFCIO_IRQ_CFG register at bit 23.  
Otherwise it is ignored.  
If MFC_NES triggers (low level), the respective outputs take their congured safe values. The internal  
emergency switch ag remains set in register MFCIO_IRQ_FLAGS even when the external pin MFC_NES is  
already driven high again.  
MFC_NES has impact on the following functional units and outputs:  
MFC IO PWM block: the PWM high and low side gate outputs are set to a dened congurable safe  
o-state.  
MFC IO GPIO block: all GPIOs that are congured as output ports via the crossbar are set to a dened  
congurable safe o-state.  
MFC IO Step and Direction block: the step outputs and internal step counters freeze.  
The MFCIO_IRQ signal will be triggered.  
Note  
The emergency ag can only be unset be either doing a reset or by actively  
writing 2 times into the MFCIO_IRQ_CFG register at bit position 23. Thereby, the  
existing IRQ mask at bit 23 must rst be set to zero and then set back to 1 again.  
This way, the internal emergency ag is unset. This can be done either by the  
local application controller or by the EtherCAT master if it has access to register  
MFCIO_IRQ_CFG.  