TPS54560  
www.ti.com  
SLVSBN0 MARCH 2013  
APPLICATION INFORMATION  
Design Guide — Step-By-Step Design Procedure  
This guide illustrates the design of a high frequency switching regulator using ceramic output capacitors. A few  
parameters must be known in order to start the design process. These requirements are typically determined at  
the system level. Calculations can be done with the aid of WEBENCH or the excel spreadsheet (slvc452) located  
on the product page. For this example, we will start with the following known parameters:  
Output Voltage  
5 V  
Transient Response 1.25 A to 3.75 A load step  
Maximum Output Current  
Input Voltage  
ΔVOUT = 4 %  
5 A  
12 V nom. 7 V to 60 V  
Output Voltage Ripple  
0.5% of VOUT  
6.5 V  
Start Input Voltage (rising VIN)  
Stop Input Voltage (falling VIN)  
5 V  
Selecting the Switching Frequency  
The first step is to choose a switching frequency for the regulator. Typically, the designer uses the highest  
switching frequency possible since this produces the smallest solution size. High switching frequency allows for  
lower value inductors and smaller output capacitors compared to a power supply that switches at a lower  
frequency. The switching frequency that can be selected is limited by the minimum on-time of the internal power  
switch, the input voltage, the output voltage and the frequency foldback protection.  
Equation 7 and Equation 8 should be used to calculate the upper limit of the switching frequency for the  
regulator. Choose the lower value result from the two equations. Switching frequencies higher than these values  
results in pulse skipping or the lack of overcurrent protection during a short circuit.  
The typical minimum on time, tonmin, is 135 ns for the TPS54560. For this example, the output voltage is 5 V and  
the maximum input voltage is 60 V, which allows for a maximum switch frequency up to 708 kHz to avoid pulse  
skipping from Equation 7. To ensure overcurrent runaway is not a concern during short circuits use Equation 8 to  
determine the maximum switching frequency for frequency foldback protection. With a maximum input voltage of  
60 V, assuming a diode voltage of 0.7 V, inductor resistance of 11 mΩ, switch resistance of 92 mΩ, a current  
limit value of 6 A and short circuit output voltage of 0.1 V, the maximum switching frequency is 855 kHz.  
For this design, a lower switching frequency of 400 kHz is chosen to operate comfortably below the calculated  
maximums. To determine the timing resistance for a given switching frequency, use Equation 5 or the curve in  
Figure 6. The switching frequency is set by resistor R3 shown in Figure 35. For 400 kHz operation, the closest  
standard value resistor is 243 kΩ.  
1
5 A x 11 mW + 5 V + 0.7 V  
60 V - 5 A x 92 mW + 0.7 V  
æ
ö
fSW(maxskip)  
=
´
= 708 kHz  
ç
÷
135ns  
è
ø
(23)  
(24)  
(25)  
8
6 A x 11 mW + 0.1 V + 0.7 V  
60 V - 6 A x 92 mW + 0.7 V  
æ
ö
fSW(shift)  
=
´
= 855 kHz  
ç
÷
135 ns  
è
ø
92417  
400 (kHz)0.991  
RT (kW) =  
= 244 kW  
Copyright © 2013, Texas Instruments Incorporated  
Submit Documentation Feedback  
21  
Product Folder Links: TPS54560  