TPS1H100-Q1
ZHCSDD8D –OCTOBER 2014–REVISED DECEMBER 2019
www.ti.com.cn
Typical Application (continued)
Current Sense
Voltage
Vcs,H
ADC Full Scale
Range
Max Normal
Operating Current
Open Load Current
Operating
Range
On-state: Current limit, thermal fault
Off-state: Open load/ short to battery
On-state:
open load/short to battery
Over
current
Normal
Figure 46. Step 1: Short-to-GND Detection in the On-State
VBAT
VS
OPEN LOAD
Vol,off
ST/CS
FAULT
OUT
Rpd
Figure 47. Step 2: Short-to-Battery Detection in the Off-State
8.2.2.2 AEC Q100-012 Test Grade A Certification
Short-circuit reliability is critical for smart high-side power switch devices. The AEC-Q100-012 standard is used to
determine the reliability of the devices when operating in a continuous short-circuit condition. Different grade
levels are specified according to the pass cycles. This device is qualified with the highest level, Grade A, 1
million times short-to-GND certification.
Three test modes are defined in the AEC Q100-012 standard. See Table 3 for cold repetitive short-circuit test –
long pulse, cold repetitive short-circuit test – short pulse, and hot repetitive short-circuit test.
34
Copyright © 2014–2019, Texas Instruments Incorporated