REGISTER AND DATA LATCH CONFIGURATION  
The TLC5970 has five writable data latches, two readable registers, and one error release address. All data  
written into or read from these registers and data latches go through the differential signal interfaces and the  
40-bit Common Shift Register. The first four most significant bits (MSBs) in the 40-bit Common Shift Register are  
used to define which internal latch the data are transferred into. Data in the 40-bit Common Shift Register are  
automatically transferred into an internal latch or data from the internal latch are automatically transferred into the  
40-bit Common Shift Register when the TLC5970 generates the internal latch signal. Figure 25 shows the shift  
register and data latch configurations. Table 7 lists the assignment of latch addresses.  
Table 7. Register/Data Latch Address Assignment  
ADDRESS (4-Bit)  
BINARY  
DECIMAL  
HEX  
READ/WRITE  
SELCTED DATA LATCH/FUNCTION  
Grayscale (GS) data latch. These data control LED  
brightness by PWM.  
0000  
0
0
W
No assigned latch. Data are not transferred when these  
addresses are selected.  
0001-1000  
1001  
1-8  
9
1-8  
9
W
Restart operation.  
If the TLC5970 is disabled because of overvoltage  
protection (OVP) or short-circuit protection (SCP), writing  
any value to the Restart Operation latch enables the  
TLC5970. Writing to this latch has no effect if the TLC5970  
is operating normally. The system should diagnose and  
correct any problems that have caused OVP or SCP before  
writing to this latch to restart the IC.  
Status Information Data (SID) Register. Writing any value  
to this register causes the SID data to be loaded into the  
40-bit Common Shift Register.  
1010  
1011  
10  
11  
A
B
R
R
EEPROM Data Read Register. Writing any value to this  
register causes the EEPROM data to be loaded into the  
40-bit Common Shift Register.  
EEPROM1 Write Data Latch (write command = A5h).  
The data in this latch program the PH on-duty, VFB target  
voltage, differential interface timing mode. and Internal latch  
pulse delay time. In order to properly program the  
EEPROM with this data, bits 35-28 must contain A5h  
(1010101b).  
1100  
12  
C
W
EEPROM Write Data Latch 2 (write commend = 5Ah).  
The data in this latch program the default Dot Correction. In  
order to properly program the EEPROM with this data, bits  
35-28 must contain 5Ah (0101010b).  
1101  
1110  
1111  
13  
14  
15  
D
E
F
W
W
W
Dot Correction (DC) Data Latch.  
The data in this latch contain OUTn DC data. When the IC  
is powered up, the data stored in EEPROM2 are  
automatically written to this latch.  
Function Control (FC) and Brightness Control (BC) Data  
Latch.  
These data control several IC functions. This latch also  
contains the Brightness Control data.  