ADS1259  
SBAS424C JUNE 2009REVISED MARCH 2010  
www.ti.com  
COMMAND DEFINITIONS  
The commands summarized in Table 19 control and configure the operation of the ADS1259. The commands  
are stand-alone, except for the register read and register write operations which require a second command byte  
plus data. CS can be taken high or held low between opcode commands but must stay low for the entire  
command operation. Note that the Read Data Continuous mode must be cancelled by the Stop Read Data  
Continuous mode opcode (SDATAC) before sending further commands.  
Table 19. Command Definitions(1)  
COMMAND  
WAKEUP  
SLEEP  
TYPE  
Control  
Control  
Control  
Control  
Control  
Control  
Control  
Data  
DESCRIPTION  
Wake up from SLEEP mode  
Begin SLEEP mode  
FIRST OPCODE BYTE  
0000 001x (02h or 03h)(2)  
0000 010x (04h or 05h)(2)  
0000 011x (06h or 07h)(2)  
0000 100x (08h or 09h)(2)  
0000 101x (0Ah or 0Bh)(2)  
0001 0000 (10h)  
SECOND OPCODE BYTE  
RESET  
Reset to power-up values  
START conversion  
START  
STOP  
STOP conversion  
RDATAC  
SDATAC  
RDATA  
RREG  
Set Read Data Continuous mode  
Stop Read Data Continuous mode  
Read data by opcode  
0001 0001 (11h)  
0001 001x (12h or 13h)(2)  
0010 rrrr (20h + 0000 rrrr)  
0100 rrrr (40h + 0000 rrrr)  
0001 1000 (18h)  
Register  
Register  
Calibration  
Calibration  
Read nnnn register at address rrrr  
Write nnnn register at address rrrr  
Offset calibration  
0000 nnnn (00h + nnnn)  
0000 nnnn (00h + nnnn)  
WREG  
OFSCAL  
GANCAL  
Gain calibration  
0001 1001 (19h)  
(1) nnnn = number of registers to be read/written – 1. For example, to read/write 3 registers, set nnnn = 2 (0010).  
rrrr = starting register address for read/write opcodes.  
(2) These commands are decoded on the seventh bit of the opcode. The eighth bit is a don't care bit. All other commands are decoded on  
the eighth bit.  
WAKEUP: Exit SLEEP Mode  
Description: This command exits the low-power SLEEP mode; see the SLEEP Mode section.  
SLEEP: Enter SLEEP Mode  
Description: This command enters the low-power SLEEP mode. See the SLEEP Mode section.  
RESET: Reset Registers to Default Values  
Description: This command resets the digital filter cycle and returns all register settings to the default values.  
START: Start Conversions  
Description: This command starts data conversions. If PULSE bit = 1, then a single conversion is performed. If  
PULSE bit = 0, then conversions continue until the STOP command is sent. Tie the START pin low to control  
conversions by command.  
STOP: Stop Conversions  
Description: This command stops conversions. When the STOP command is sent, the conversion in progress  
completes and further conversions are stopped. If conversions are already stopped, this command has no effect.  
See the Conversion Control section. Tie the START pin low to control conversions by command.  
RDATAC: Read Data Continuous  
Description: This command enables the Read Data Continuous mode (default). See the Read Data Continuous  
Mode section for details. Disable this mode with the SDATAC command before sending other commands.  
SDATAC: Stop Read Data Continuous  
Description: This command cancels the Read Data Continuous mode.  
32  
Submit Documentation Feedback  
Copyright © 2009–2010, Texas Instruments Incorporated  
Product Folder Link(s): ADS1259  
 