DAC8571
www.ti.com
C<5> C<4>
SLAS373A–DECEMBER 2002–REVISED JULY 2003
C<2>
0
1
1
1
1
0
1
1
0
0
0
1
MS and LS bytes represent temporary and DAC register data
MS and LS bytes represent I2C data that is discarded
MS and LS bytes represent I2C data that is discarded
MS and LS bytes represent temporary and DAC register data
EXAMPLES (A0 TIED TO GND, VDD = 5 V)
EXAMPLE 1: Write 1/4 scale to DAC8571
ADDRESS <7...0>
1001 1000
C<7...0>
M<7...0>
L<7...0>
START
ACK
0001 0000
ACK
ACK
ACK
ACK
0100 0000
ACK
ACK
ACK
ACK
ACK
ACK
ACK
ACK
ACK
0000 0000
ACK
STOP
Previous output voltage is valid
EXAMPLE 2: Switch DAC8571 to fast settling mode
Vout = 1.25 V
ADDRESS <7...0>
1001 1000
C<7...0>
M<7...0>
L<7...0>
START
ACK
0001 0001
0010 0000
0000 0000
ACK
STOP
Previous output voltage is valid
EXAMPLE 3: Switch DAC8571 back to low power mode
Vout = 0 V
ADDRESS <7...0>
1001 1000
C<7...0>
M<7...0>
L<7...0>
START
ACK
0001 0001
0000 0000
0000 0000
ACK
STOP
Previous output voltage is valid
EXAMPLE 4: Power-down DAC8571 with Hi-Z output
Vout = 0 V
ADDRESS <7...0>
1001 1000
C<7...0>
M<7...0>
L<7...0>
START
ACK
0001 0001
1100 0000
0000 0000
ACK
STOP
Previous output voltage is valid
EXAMPLE 5: Power-down DAC8571 with 1K output impedance to ground
Vout = Hi-Z
ADDRESS <7...0>
1001 1000
C<7...0>
M<7...0>
L<7...0>
START
ACK
0001 0001
ACK
0100 0000
0000 0000
ACK
STOP
Previous output voltage is valid
EXAMPLE 6: Power-down DAC8571 with 100K output impedance to ground
Vout = 0 V
ADDRESS <7...0>
1001 1000
C<7...0>
M<7...0>
L<7...0>
START
ACK
0001 0001
ACK
1000 0000
0000 0000
ACK
STOP
Previous output voltage is valid
EXAMPLE 7: Store full scale data in temporary register
Vout = 0 V
ADDRESS <7...0>
1001 1000
C<7...0>
M<7...0>
L<7...0>
START
ACK
0000 0000
ACK
1111 1111
1111 1111
ACK
STOP
Previous output voltage is valid
EXAMPLE 8: Update DAC8571 with the data previously stored in the temporary register
ADDRESS <7...0>
1001 1000
C<7...0>
M<7...0>
L<7...0>
START
ACK
0010 0000
ACK
XXXX XXXX
XXXX XXXX
ACK
STOP
Previous output voltage is valid
EXAMPLE 9: Broadcast a powerdown command to all DAC8571s on the I2C bus
New Vout valid
ADDRESS <7...0>
1001 0000
C<7...0>
M<7...0>
L<7...0>
START
ACK
0011 0101
ACK
1100 0000
0000 0000
ACK
Vout = Hi-Z
STOP
Previous output voltage is valid
EXAMPLE 10: Broadcast update. All DAC8571s on the I2C bus update synchronously with the contents of their temporary
registers
ADDRESS <7...0>
1001 0000
C<7...0>
M<7...0>
L<7...0>
START
ACK
0011 0000
ACK
XXXX XXXX
ACK
XXXX XXXX
ACK
STOP
Previous output voltage is valid
New Vout valid
21