M27C2001
Table 7. Read Mode DC Characteristics
(1)
(TA = 0 to 70
°C
or –40 to 85
°C;
V
CC
= 5V
±
5% or 5V
±
10%; V
PP
= V
CC
)
Symbol
I
LI
I
LO
I
CC
I
CC1
I
CC2
I
PP
V
IL
V
IH (2)
V
OL
V
OH
Parameter
Input Leakage Current
Output Leakage Current
Supply Current
Supply Current (Standby) TTL
Supply Current (Standby) CMOS
Program Current
Input Low Voltage
Input High Voltage
Output Low Voltage
Output High Voltage TTL
Output High Voltage CMOS
I
OL
= 2.1mA
I
OH
= –400µA
I
OH
= –100µA
2.4
V
CC
– 0.7V
Test Condition
0V
≤
V
IN
≤
V
CC
0V
≤
V
OUT
≤
V
CC
E = V
IL
, G = V
IL
,
I
OUT
= 0mA, f = 5MHz
E = V
IH
E > V
CC
– 0.2V
V
PP
= V
CC
–0.3
2
Min
Max
±10
±10
30
1
100
10
0.8
V
CC
+ 1
0.4
Unit
µA
µA
mA
mA
µA
µA
V
V
V
V
V
Note: 1. V
CC
must be applied simultaneously with or before V
PP
and removed simultaneously or after V
PP
.
2. Maximum DC voltage on Output is V
CC
+0.5V.
Table 8A. Read Mode AC Characteristics
(1)
(TA = 0 to 70
°C
or –40 to 85
°C;
V
CC
= 5V
±
5% or 5V
±
10%; V
PP
= V
CC
)
M27V2001
Symbol
Alt
Parameter
Test Condition
-55
(3)
Min
t
AVQV
t
ELQV
t
GLQV
t
EHQZ (2)
t
GHQZ (2)
t
AXQX
t
ACC
t
CE
t
OE
t
DF
t
DF
t
OH
Address Valid to
Output Valid
Chip Enable Low to
Output Valid
Output Enable Low
to Output Valid
Chip Enable High to
Output Hi-Z
Output Enable High
to Output Hi-Z
Address Transition to
Output Transition
E = V
IL
, G = V
IL
G = V
IL
E = V
IL
G = V
IL
E = V
IL
E = V
IL
, G = V
IL
0
0
0
-70
-80
-90
Min Max
90
90
40
0
0
0
30
30
ns
ns
ns
ns
ns
ns
Unit
Max Min
55
55
30
30
30
0
0
0
Max Min Max
70
70
35
30
30
0
0
0
80
80
40
30
30
Note: 1. V
CC
must be applied simultaneously with or before V
PP
and removed simultaneously or after V
PP
.
2. Sampled only, not 100% tested.
3. In case of 45ns speed see High Speed AC measurament conditions.