L7250  
Figure 13. VCM Bemf Offset CALIBRATION Routine  
START  
VCM Bemf offset calibration  
Routine  
Set VCM in Tristate  
Write Reg.03H  
VCMState[2:0] = 001  
Set ADC Clock  
Write Reg.06H  
PREADC[1:0] = 01  
START 10Bit ADC Conversion  
of the BEMF Channel  
Write Reg.0CH  
ADC_CH_ADDR[1:0] =10  
ADC_START=1  
Wait End of  
Conversion  
NO  
Read 10Bit ADC  
Read Reg.0BH  
YES  
OPTIONAL  
ADC_DATA[9:2]  
Read Reg.0CH  
ADC_DATA[1:0]  
Latch Offset Compensation  
Write Reg.03H  
BemfOffCal = 1  
then  
BemfOffCal = 0  
To restart this routine is mandatory to start  
First the clear routine (see Fig. 10)  
EXIT  
VCM Bemf offset calibration  
At the end of the calibration routine the analog value measured at pin 31 is rapresenting the VCM BEMF value  
at the zero motion (BEMF zero value). With the ADC it is possible to operate a new convertion in order to mem-  
orize this value and to take in account of it during the load/unload procedure.  
3.8.4 Power Off Unload - Active brake and constant voltage unload operation  
In case of power shut down, an unload procedure start automatically in order to take the heads over the ramp  
in the parking position (the same procedure can be also enabled, when the power is on, via serial port program-  
ming the unload/retract status of the VCM -> reg. 03H. In this case at the end of the unload phase the spindle  
motor is driven in tri-state condition).  
The unload procedure doesn’t start at power off if the VCM status bit are set to 000 because the system is con-  
sidering the heads already in park position. No entering the unload procedure also the spindle brake is not ac-  
tivated.  
The unload procedure is done in two step:  
- active brake  
- constant voltage unload operation  
The unload procedure take place only if the VCM status bit have moved from the 000 configuration. Otherwise  
the unload procedure doesn't start and in case of power shut down the spindle motor enter the brake condition.  
Active Brake : it is used to have a fast recovery of the VCM velocity down to the unload programmed velocity.  
If just before a power shut down a fast seek was commanded, it is necessary to recover the VCM velocity in  
34/46  