欢迎访问ic37.com |
会员登录 免费注册
发布采购

FDC37C669_07 参数 Datasheet PDF下载

FDC37C669_07图片预览
型号: FDC37C669_07
PDF下载: 下载PDF文件 查看货源
内容描述: 98/99 PC兼容的超级I / O软盘控制器,红外支持 [PC 98/99 Compliant Super I/O Floppy Disk Controller with Infrared Support]
分类和应用: 控制器PC
文件页数/大小: 164 页 / 575 K
品牌: SMSC [ SMSC CORPORATION ]
 浏览型号FDC37C669_07的Datasheet PDF文件第100页浏览型号FDC37C669_07的Datasheet PDF文件第101页浏览型号FDC37C669_07的Datasheet PDF文件第102页浏览型号FDC37C669_07的Datasheet PDF文件第103页浏览型号FDC37C669_07的Datasheet PDF文件第105页浏览型号FDC37C669_07的Datasheet PDF文件第106页浏览型号FDC37C669_07的Datasheet PDF文件第107页浏览型号FDC37C669_07的Datasheet PDF文件第108页  
OPERATION  
After negotiation, it is necessary to initialize  
some of the port bits. The following are required:  
Mode Switching/Software Control  
Software will execute P1284 negotiation and all  
operation prior to a data transfer phase under  
programmed I/O control (mode 000 or 001).  
Hardware provides an automatic control line  
handshake, moving data between the FIFO and  
the ECP port only in the data transfer phase  
(modes 011 or 010).  
Set Direction = 0, enabling the drivers.  
Set strobe = 0, causing the nStrobe signal  
to default to the deasserted state.  
Set autoFd = 0, causing the nAutoFd signal  
to default to the deasserted state.  
·
·
·
·
Set mode = 011 (ECP Mode)  
ECP address/RLE bytes or data bytes may be  
sent automatically by writing the ecpAFifo or  
ecpDFifo respectively.  
Setting the mode to 011 or 010 will cause the  
hardware to initiate data transfer.  
If the port is in mode 000 or 001 it may switch to  
any other mode. If the port is not in mode 000  
or 001 it can only be switched into mode 000 or  
001. The direction can only be changed in  
mode 001.  
Note that all FIFO data transfers are byte wide  
and byte aligned. Address/RLE transfers are  
byte-wide and only allowed in the forward  
direction.  
The host may switch directions by first switching  
to mode = 001, negotiating for the forward or  
reverse channel, setting direction to 1 or 0, then  
setting mode = 011. When direction is 1 the  
hardware shall handshake for each ECP read  
data byte and attempt to fill the FIFO. Bytes  
may then be read from the ecpDFifo as long as  
it is not empty .  
Once in an extended forward mode the software  
should wait for the FIFO to be empty before  
switching back to mode 000 or 001. In this case  
all control signals will be deasserted before the  
mode switch. In an ecp reverse mode the  
software waits for all the data to be read from  
the FIFO before changing back to mode 000 or  
001. Since the automatic hardware ecp reverse  
handshake only cares about the state of the  
FIFO it may have acquired extra data which will  
be discarded. It may in fact be in the middle of a  
transfer when the mode is changed back to 000  
or 001. In this case the port will deassert  
nAutoFd independent of the state of the transfer.  
The design shall not cause glitches on the  
handshake signals if the software meets the  
constraints above.  
ECP transfers may also be accomplished (albeit  
slowly) by handshaking individual bytes under  
program control in mode = 001, or 000.  
Termination from ECP Mode  
Termination from ECP Mode is similar to the  
termination from Nibble/Byte Modes. The host is  
permitted to terminate from ECP Mode only in  
specific well-defined states. The termination can  
only be executed while the bus is in the forward  
direction. To terminate while the channel is in  
the reverse direction, it must first be transitioned  
into the forward direction.  
ECP Operation  
Prior to ECP operation the Host must negotiate  
on the parallel port to determine if the peripheral  
supports the ECP protocol. This is a somewhat  
complex negotiation carried out under program  
control in mode 000.  
104  
 复制成功!