 浏览型号FDC37C669_07的Datasheet PDF文件第96页浏览型号FDC37C669_07的Datasheet PDF文件第97页浏览型号FDC37C669_07的Datasheet PDF文件第98页浏览型号FDC37C669_07的Datasheet PDF文件第99页浏览型号FDC37C669_07的Datasheet PDF文件第101页浏览型号FDC37C669_07的Datasheet PDF文件第102页浏览型号FDC37C669_07的Datasheet PDF文件第103页浏览型号FDC37C669_07的Datasheet PDF文件第104页  
DATA and ecpAFifo PORT  
ADDRESS OFFSET = 00H  
BIT 5 PError  
The level on the PError input is read by the CPU  
as bit 5 of the Device Status Register. Printer  
Status Register.  
Modes 000 and 001 (Data Port)  
The Data Port is located at an offset of '00H'  
from the base address. The data register is  
cleared at initialization by RESET. During a  
WRITE operation, the Data Register latches the  
contents of the data bus on the rising edge of  
the nIOW input. The contents of this register  
are buffered (non inverting) and output onto the  
PD0 - PD7 ports. During a READ operation,  
PD0 - PD7 ports are read and output to the host  
CPU.  
BIT 6 nAck  
The level on the nAck input is read by the  
CPU as bit 6 of the Device Status Register.  
BIT 7 nBusy  
The complement of the level on the BUSY input  
is read by the CPU as bit 7 of the Device Status  
Register.  
DEVICE CONTROL REGISTER (dcr)  
ADDRESS OFFSET = 02H  
Mode 011 (ECP FIFO - Address/RLE)  
The Control Register is located at an offset of  
'02H' from the base address. The Control  
Register is initialized to zero by the RESET  
input, bits 0 to 5 only being affected; bits 6 and  
7 are hard wired low.  
A data byte written to this address is placed in  
the FIFO and tagged as an ECP Address/RLE.  
The hardware at the ECP port transmits this  
byte to the peripheral automatically.  
The  
operation of this register is only defined for the  
forward direction (direction is 0). Refer to the  
ECP Parallel Port Forward Timing Diagram,  
located in the Timing Diagrams section of this  
data sheet.  
BIT 0 STROBE - STROBE  
This bit is inverted and output onto the  
nSTROBE output.  
BIT 1 AUTOFD - AUTOFEED  
DEVICE STATUS REGISTER (dsr)  
ADDRESS OFFSET = 01H  
This bit is inverted and output onto the  
nAUTOFD output. A logic 1 causes the printer  
to generate a line feed after each line is printed.  
A logic 0 means no autofeed.  
The Status Port is located at an offset of '01H'  
from the base address. Bits 0 - 2 are not  
implemented as register bits, during a read of  
the Printer Status Register these bits are a low  
level. The bits of the Status Port are defined as  
follows:  
BIT 2 nINIT - nINITIATE OUTPUT  
This bit is output onto the nINIT output without  
inversion.  
BIT 3 SELECTIN  
This bit is inverted and output onto the nSLCTIN  
output. A logic 1 on this bit selects the printer; a  
logic 0 means the printer is not selected.  
BIT 3 nFault  
The level on the nFault input is read by the CPU  
as bit 3 of the Device Status Register.  
BIT 4 ackIntEn - INTERRUPT REQUEST  
ENABLE  
BIT 4 Select  
The level on the Select input is read by the CPU  
as bit 4 of the Device Status Register.  
The interrupt request enable bit when set to a  
high level may be used to enable interrupt  
100  