Fan Control Device with Hardware Monitoring and Acoustic Noise Reduction Features  
Datasheet  
BIT  
NAME  
R/W DEFAULT  
DESCRIPTION  
0
2.5V_Error  
R
R
R
R
R
0
0
0
0
0
The EMC6D102 automatically sets this bit to 1 when the 2.5V input  
voltage is less than or equal to the limit set in the 2.5V Low Limit register  
or greater than the limit set in the 2.5V High Limit register.  
The EMC6D102 automatically sets this bit to 1 when the Vccp input  
voltage is less than or equal to the limit set in the Vccp Low Limit register  
or greater than the limit set in the Vccp High Limit register.  
The EMC6D102 automatically sets this bit to 1 when the VCC input  
voltage is less than or equal to the limit set in the VCC Low Limit register  
or greater than the limit set in the VCC High Limit register.  
The EMC6D102 automatically sets this bit to 1 when the 5V input voltage  
is less than or equal to the limit set in the 5V Low Limit register or greater  
than the limit set in the 5V High Limit register.  
1
2
3
4
Vccp_Error  
VCC_Error  
5V_Error  
Remote  
Diode 1 Limit  
Error  
The EMC6D102 automatically sets this bit to 1 when the temperature  
input measured by the Remote1- and Remote1+ is less than or equal to  
the limit set in the Remote Diode 1 Low Temp register or greater than the  
limit set in Remote Diode 1 High Temp register.  
5
6
Internal  
Sensor Limit  
Error  
R
R
R
0
0
0
The EMC6D102 automatically sets this bit to 1 when the temperature  
input measured by the internal temperature sensor is less than or equal  
to the limit set in the Internal Low Temp register or greater than the limit  
set in the Internal High Temp register.  
The EMC6D102 automatically sets this bit to 1 when the temperature  
input measured by the Remote2- and Remote2+ is less than or equal to  
the limit set in the Remote Diode 2 Low Temp register or greater than the  
limit set in the Remote Diode 1 High Temp register.  
Remote  
Diode 2 Limit  
Error  
7
INT2 Event  
Active  
The device automatically sets this bit to 1 when a status bit is set in the  
Interrupt Status Register 2.  
7.2.11  
Register 42h: Interrupt Status Register 2  
Register  
Address  
Read/  
Bit 7  
Bit 0  
Default  
Value  
Register Name  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Write  
(MSb)  
(LSb)  
42h  
R-C  
(See  
Note  
7.10)  
Interrupt Status Register 2  
ERR2  
ERR1  
TACH4  
TACH3  
TACH2  
TACH1  
RES  
12V  
00h  
Note 7.10 This register is cleared on a read if no events are active.  
This register is read only – a write to this register has no effect.  
The Interrupt Status Register 2 bits is automatically set by the device whenever a remote temperature  
sensor error occurs, a tach reading value is above the minimum value set in the tachometer minimum  
registers, or whenever the 12V input voltage violates the limits set in the limit and parameter registers.  
The Interrupt Status Register 2 register holds a set bit until the event is read by software or until the  
individual interrupt enable bit is cleared.  
This register holds a bit set until the event is read by software or until the individual enable bit is  
cleared (see Note below). The contents of this register are cleared (set to 0) automatically by the  
EMC6D102 after it is read by software, if the voltage no longer violate the limits set in the limit and  
parameter registers, if the temperature sensor error no loner exists, or if the tach reading register is  
no longer above the minimum. Once set, the Interrupt Status Register 2 bits remain set until a read  
event occurs or until the individual interrupt enable bit is cleared, even if the voltage, Tach, or diode  
event no longer exists.  
The remote diode fault bits do not clear on a read while the fault condition exists. If the start bit is set  
when a fault condition occurs, 80h will be loaded into the associated temperature reading register,  
which will cause the associated diode limit error bit to be set (Remote Diode 1 Limit Error or Remote  
SMSC EMC6D102  
Revision 0.4 (04-05-05)  
DATA5S5HEET