Fan Control Device with Hardware Monitoring and Acoustic Noise Reduction Features  
Datasheet  
7.2.6  
Registers 30-32h: Current PWM Duty  
Register  
Address  
Read/  
Write  
Bit 7  
Bit 0  
Default  
Value  
Register Name  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
(MSb)  
(LSb)  
30h  
31h  
32h  
PWM1 Current Duty Cycle  
7
7
7
6
5
4
3
2
1
0
0
0
N/A  
N/A  
N/A  
R/W  
(See  
Note 7.8)  
PWM2 Current Duty Cycle  
PWM3 Current Duty Cycle  
6
6
5
5
4
4
3
3
2
2
1
1
R/W  
(See  
Note 7.8)  
R/W  
(See  
Note 7.8)  
Note 7.8 These registers are only writable when the associated fan is in manual mode. These  
registers become read only when the Lock bit is set. Any further attempts to write to these  
registers shall have no effect.  
The Current PWM Duty registers store the duty cycle that the chip is currently driving the PWM signals  
at. At initial power-on, the duty cycle is 100% and thus, when read, this register will return FFh. After  
the Ready/Lock/Start Register Start bit is set, this register and the PWM signals are updated based  
on the algorithm described in the Auto Fan Control Operating Mode section and the Ramp Rate  
Control logic, unless the associated fan is in manual mode – see below.  
Note: When the device is configured for Manual Mode, the Ramp Rate Control logic should be  
disabled.  
When read, the Current PWM Duty registers return the current PWM duty cycle for the respective  
PWM signal.  
These registers are read only – a write to these registers has no effect.  
Note: If the current PWM duty cycle registers are written while the part is not in manual mode or  
when the start bit is zero, the data will be stored in internal registers that will only be active  
and observable when the start bit is set and the fan is configured for manual mode. While the  
part is not in manual mode and the start bit is zero, the current PWM duty cycle registers will  
read back FFh.  
Manual Mode (Test Mode)  
In manual mode, when the start bit is set to 1 and the lock bit is 0, the current duty cycle registers are  
writeable to control the PWMs.  
Note: When the lock bit is set to 1, the current duty cycle registers are Read-Only.  