 浏览型号COM20020I3V-HT的Datasheet PDF文件第46页浏览型号COM20020I3V-HT的Datasheet PDF文件第47页浏览型号COM20020I3V-HT的Datasheet PDF文件第48页浏览型号COM20020I3V-HT的Datasheet PDF文件第49页浏览型号COM20020I3V-HT的Datasheet PDF文件第51页浏览型号COM20020I3V-HT的Datasheet PDF文件第52页浏览型号COM20020I3V-HT的Datasheet PDF文件第53页浏览型号COM20020I3V-HT的Datasheet PDF文件第54页  
5Mbps ARCNET (ANSI 878.1) Controller with 2K x 8 On-Chip RAM  
AD0-AD2,  
D3-D7  
VALID DATA  
VALID  
t3  
t1  
t2,  
t4  
nCS  
t12  
t11  
ALE  
nDS  
t7  
t5  
t6  
Note 2  
t8**  
t13  
t8  
t14  
t10  
DIR  
t9  
Parameter  
min  
max  
units  
t1  
t2  
t3  
t4  
t5  
t6  
t7  
t8  
t9  
t10  
t11  
t12  
t13  
t14  
Address Setup to ALE Low  
Address Hold from ALE Low  
nCS Setup to ALE Low  
nCS Hold from ALE Low  
ALE Low to nDS Low  
nS  
nS  
nS  
nS  
nS  
nS  
nS  
nS  
nS  
nS  
nS  
nS  
nS  
nS  
20  
10  
10  
10  
15  
30  
10  
Valid Data Setup to nDS High  
Data Hold from nDS High  
Cycle Time (nDS  
to Next  
)**  
4TARB*  
10  
DIR Setup to nDS Active  
DIR Hold from nDS Inactive  
ALE High Width  
ALE Low Width  
nDS Low Width  
10  
20  
20  
20  
20  
nDS High Width  
*
TARB is the Arbitration Clock Period  
TARB is identical to Topr if SLOW ARB = 0  
TARB is twice Topr if SLOW ARB = 1  
Topr is the period of operation clock. It depends on CKUP1 and CKUP0 bits  
The Microcontroller typically accesses the COM20020 on every other cycle.  
Therefore, the cycle time specified in the microcontroller's datasheet  
should be doubled when considering back-to-back COM20020 cycles.  
Note 1:  
**  
Any cycle occurring after a write to Address Pointer Low Register requires a  
minimum of 4TARB from the trailing edge of nDS to the leading edge of the  
next nDS.  
Note 2:  
Write cycle for Address Pointer Low Register occurring after an access to  
Data Register requires a minimum of 5TARB from the trailing edge of nDS to  
the leading edge of the next nDS.  
FIGURE 13 - MULTIPLEXED BUS, 68XX-LIKE CONTROL SIGNALS; WRITE CYCLE  