R×5C348A/B  
2.1-5 CT2, CT1, and CT0  
Periodic Interrupt Selection Bits  
Description  
Interrupt cycle and fall timing  
CT2  
CT1  
CT0  
Waveform mode  
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
Off (“H”)  
Fixed at low (“L”)  
(Default setting)  
Pulse Mode 2Hz (Duty cycle of 50%)  
Pulse Mode 1Hz (Duty cycle of 50%)  
Level Mode Once per 1 second (Synchronized with second counter increment)  
Level Mode Once per minute (at 00 seconds of every minute)  
Level Mode Once per hour (at 00 minutes and 00 seconds of every hour)  
Level Mode Once per month (at 00 hours, 00 minutes, and 00 seconds of first day of every month)  
1) Pulse Mode: 2-Hz and 1-Hz clock pulses are output in synchronization with the increment of the second counter  
as illustrated in the timing chart on the next page.  
2) Level Mode: periodic interrupt signals are output with selectable interrupt cycle settings of 1 second, 1 minute,  
1 hour, and 1 month. The increment of the second counter is synchronized with the falling edge of  
periodic interrupt signals. For example, periodic interrupt signals with an interrupt cycle setting  
of 1 second are output in synchronization with the increment of the second counter as illustrated  
in the timing chart on the next page.  
3) When the oscillation adjustment circuit is used, the interrupt cycle will fluctuate once per 20 seconds as follows:  
Pulse Mode: the “L” period of output pulses will increment or decrement by a maximum of 3.784ms.  
For example, 1-Hz clock pulses will have a duty cycle of 50 0.3784%.  
Level Mode: a periodic interrupt cycle of 1 second will increment or decrement by a maximum of 3.784ms.  