7.2.10
Execution Times Break Register (BETR)
When the execution-times break condition of channel B is enabled, this register specifies the
number of execution times to make the break. The maximum number is 212 – 1 times. A power-on
reset initializes BETR to H'0000. When a break condition is satisfied, it decreases the BETR. A
break is issued when the break condition is satisfied after the BETR becomes H'0001. Bits 15-12
are always read as 0 and 0 should always be written in these bits.
Bit:
15
—
0
14
—
0
13
—
0
12
—
0
11
10
9
8
Initial value:
R/W:
0
0
0
0
R
R
R
R
R/W
R/W
R/W
R/W
Bit:
7
6
5
4
3
2
1
0
Initial value:
R/W:
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W